Effect of curing temperature in some hydration characteristics of calcium aluminate cement compared with those of portland cement

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/12328
Información del item - Informació de l'item - Item information
Títol: Effect of curing temperature in some hydration characteristics of calcium aluminate cement compared with those of portland cement
Autors: Garcés, Pedro | García Alcocel, Eva María | Chinchón Yepes, Servando | García Andreu, César | Alcaide Romero, Juan
Grups d'investigació o GITE: Materiales y Sistemas Constructivos de la Edificación | Durabilidad de Materiales y Construcciones en Ingeniería y Arquitectura | Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas | Tecnología de Materiales y Territorio (TECMATER)
Centre, Departament o Servei: Universidad de Alicante. Departamento de Construcciones Arquitectónicas | Universidad de Alicante. Departamento de Ingeniería de la Construcción, Obras Públicas e Infraestructura Urbana
Paraules clau: Calcium Aluminate Cement | Portland Cement | XRD
Àrees de coneixement: Construcciones Arquitectónicas
Data de publicació: de setembre-1997
Editor: Elsevier
Citació bibliogràfica: GARCÉS TERRADILLOS, Pedro, et al. "Effect of curing temperature in some hydration characteristics of calcium aluminate cement compared with those of portland cement". Cement and Concrete Research. Vol. 27, Issue 9 (Sept. 1997). ISSN 0008-8846, pp. 1343-1355
Resum: In the present paper the hydration of 1:3 Calcium Aluminate Cement (CAC) and Portland Cement (PC) mortars at temperatures of 5 degrees C, 20 degrees C, and 60 degrees C have been studied. An evaluation of the compressive and flexural strengths obtained from different curing conditions is made. The evolution of phases presented was also studied from XRD spectra. The relationship between the values of ultrasonic propagation velocity, UPV, (Y1-axis) and compressive strengths (Y2-axis) versus w/c ratios for CAC mortars, cured at 5 degrees C, 20 degrees C and 60 degrees C respectively, have also been obtained, at a curing age of 28 days. The great similarity of curves enables us to establish the hypothesis that it is possible to use a non destructive test as an empirical determination of compressive strength for CAC mortars with the same proportions of aggregates/cements/water as those used in the test. Abrams rule was applied in order to check the reality of this model in the CAC mortars studied. The percentage of variability of the variable response (Rc), obtained in our regression models is highly satisfactory.
Patrocinadors: Generalitat Valenciana (Spain) (GV-1 159/93).
URI: http://hdl.handle.net/10045/12328
ISSN: 0008-8846 (Print) | 1873-3948 (Online)
DOI: 10.1016/S0008-8846(97)00136-1
Idioma: eng
Tipus: info:eu-repo/semantics/article
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/S0008-8846(97)00136-1
Apareix a la col·lecció: INV - MSCE - Artículos de Revistas
INV - DMCIA - Artículos de Revistas
INV - TECMATER - Artículos de Revistas
INV - ALISoft - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnails9.EFFECT OF CURING TEMPERATURE IN SOME HYDRATION.pdfVersión final (acceso restringido)782,4 kBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.