The Passivhaus Standard in the Spanish Mediterranean: Evaluation of a House’s Thermal Behaviour of Enclosures and Airtightness

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/94015
Información del item - Informació de l'item - Item information
Títol: The Passivhaus Standard in the Spanish Mediterranean: Evaluation of a House’s Thermal Behaviour of Enclosures and Airtightness
Autors: Echarri-Iribarren, Víctor | Sotos-Solano, Cristina | Espinosa Fernández, Almudena | Prado Govea, Raúl Hugo
Grups d'investigació o GITE: Tecnología y Sostenibilidad en Arquitectura | Grupo de Investigación en Restauración Arquitectónica de la Universidad de Alicante. GIRAUA-CICOP
Centre, Departament o Servei: Universidad de Alicante. Departamento de Construcciones Arquitectónicas
Paraules clau: Passivhaus | Thermal transmittance of enclosures | Air infiltration | Annual energy demand | Energy efficiency
Àrees de coneixement: Construcciones Arquitectónicas
Data de publicació: 8-de juliol-2019
Editor: MDPI
Citació bibliogràfica: Echarri-Iribarren V, Sotos-Solano C, Espinosa-Fernández A, Prado-Govea R. The Passivhaus Standard in the Spanish Mediterranean: Evaluation of a House’s Thermal Behaviour of Enclosures and Airtightness. Sustainability. 2019; 11(13):3732. doi:10.3390/su11133732
Resum: Few houses have been built in the Spanish Mediterranean in accordance with the Passivhaus (PH) standard. This standard is adapted to the continental climates of Central Europe and thorough studies are necessary to apply this standard in Spain, especially in the summer. High relative air humidity levels in coastal areas and solar radiation levels of west-facing façades require adapted architectural designs, as well as greater control of air renewal and dehumidification. A priori, energy consumptions undergo big variations. In this study, the construction of a single-family house in the Spanish Levante was analysed. All enclosure layers were monitored using sensors of surface temperature, solar radiation, indoor and outdoor air temperature, relative humidity, and air speed. The thermal behaviour of the façade enclosure and air infiltration through the enclosure were examined using the blower door test and impacts on annual energy demand were quantified. Using simulation tools, improvements are proposed, and the results are compared with examples of PH housing in other geographical areas. The annual energy demand of PH housing was 69.19% below the usual value for buildings in the Mediterranean region. Very thick thermal insulation and low values of airtightness could be applied to the envelope, which would work very well in the winter. These technique solutions could provide optimal comfort conditions with a well-designed air conditioning system in summer and low energy consumption.
Patrocinadors: This research has been funded by the Vicerectorate of Campus Facilities & Technology of the Universidad de Alicante, ref. 2018 34406P0002 P102 68000 (VIGROB 223).
URI: http://hdl.handle.net/10045/94015
ISSN: 2071-1050
DOI: 10.3390/su11133732
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Revisió científica: si
Versió de l'editor: https://doi.org/10.3390/su11133732
Apareix a la col·lecció: INV - TSA - Artículos de Revistas
INV - GIRAUA-CICOP - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2019_Echarri-Iribarren_etal_Sustainability.pdf5,46 MBAdobe PDFObrir Vista prèvia


Aquest ítem està subjecte a una llicència de Creative Commons Llicència Creative Commons Creative Commons