Knee kinematics of ACL-deficient patients: A development of a portable motion analysis system

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/77859
Información del item - Informació de l'item - Item information
Title: Knee kinematics of ACL-deficient patients: A development of a portable motion analysis system
Authors: Fung, Pui Wa | Mok, Kam-Ming | Leow, Ruen Shan | Fu, Sai Chuen | Yung, Patrick Shu-Hang | Chan, Kai Ming
Keywords: Anterior cruciate ligament | Dynamic knee stability | Sports injury | Stair descent | Tibiofemoral kinematics
Knowledge Area: Educación Física y Deportiva
Issue Date: 2018
Publisher: Universidad de Alicante. Área de Educación Física y Deporte
Citation: Journal of Human Sport and Exercise. 2018, 13(4): 832-842. doi:10.14198/jhse.2018.134.11
Abstract: This study is to compare the knee kinematic measurements between the novel portable skin marker-based motion analysis system (Opti-Knee®) and a conventional system (Vicon®). Nineteen subjects were recruited and asked to perform stair descent with lower limb placed with skin markers. Knee kinematic data was computed from the trajectories of the skin markers. Pearson’s correlation coefficient and Root-mean-square deviation (RMSD) were used to analyze the data. For the waveform, sagittal plane rotation is strongly positive correlated between systems, while for axial and coronal plane rotation, it was moderately to strongly positive correlated in both normal (ACLN) and ACL-deficient (ACLD) group. Substantial difference between two groups was found in correlation of abduction/adduction in both stance and swing phase, as well as in external/internal rotation in all selected regions of interest. Moreover, the RMSD was larger in ACLN than in ACLD in three planes of rotation. The capability of Opti-Knee® in tracking lower limb sagittal plane rotation was comparable to Vicon®. However, for coronal and axial plane rotation, although the correlation to Vicon® in kinematic waveforms was moderately high, their ROM and peak values substantially deviated from the values in Vicon®.
Sponsor: This study is supported by the Innovation and Technology Support Program, Hong Kong (Ref. No.: ITS/289/14FX).
URI: https://doi.org/10.14198/jhse.2018.134.11 | http://hdl.handle.net/10045/77859
ISSN: 1988-5202
DOI: 10.14198/jhse.2018.134.11
Language: eng
Type: info:eu-repo/semantics/article
Rights: Licencia Creative Commons Reconocimiento-NoComercial-SinObraDerivada 4.0
Peer Review: si
Publisher version: https://www.jhse.ua.es/
Appears in Collections:Journal of Human Sport and Exercise - 2018, Vol. 13, No. 4

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailJHSE_13-4_11.pdf509,24 kBAdobe PDFOpen Preview


This item is licensed under a Creative Commons License Creative Commons