A modified ZSM-5 zeolite/Fe2O3 composite as a sorbent for magnetic dispersive solid-phase microextraction of cadmium, mercury and lead from urine samples prior to inductively coupled plasma optical emission spectrometry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/75095
Información del item - Informació de l'item - Item information
Título: A modified ZSM-5 zeolite/Fe2O3 composite as a sorbent for magnetic dispersive solid-phase microextraction of cadmium, mercury and lead from urine samples prior to inductively coupled plasma optical emission spectrometry
Autor/es: Baile, Paola | Vidal, Lorena | Aguirre Pastor, Miguel Ángel | Canals, Antonio
Grupo/s de investigación o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Palabras clave: ZSM-5 zeolite | Magnetic dispersive solid-phase microextraction | Inductively coupled plasma optical emission spectrometry | Cadmium | Mercury | Lead | Urine samples
Área/s de conocimiento: Química Analítica
Fecha de publicación: 27-mar-2018
Editor: Royal Society of Chemistry
Cita bibliográfica: Journal of Analytical Atomic Spectrometry. 2018, 33: 856-866. doi:10.1039/C7JA00366H
Resumen: The purpose of this work is to present a simple, fast, cost effective and environmentally friendly magnetic dispersive solid-phase microextraction (MDSPME) method, employing a composite based on ZSM-5 zeolite decorated with iron oxide magnetic nanoparticles (i.e., ZSM-5/Fe2O3) as a valuable sorbent, for the simultaneous separation and preconcentration of cadmium (Cd), mercury (Hg) and lead (Pb) from urine samples for subsequent measurement by inductively coupled plasma optical emission spectrometry. The composite was first saturated with zinc and then modified with a hexadecyltrimethylammonium bromide surfactant and sodium diethyldithiocarbamate trihydrate chelating agent. A two-step multivariate strategy, using Plackett–Burman and circumscribed central composite designs, has been employed to optimize experimental parameters affecting MDSPME. The method has been evaluated under optimized extraction conditions (i.e., amount of sorbent, 50 mg; sample pH, 4.0; extraction time, 3 min; eluent solvent, nitric acid; eluent solvent volume, 432 μL; eluent solvent concentration, 11.8 M and elution time, 2 min) using standard addition calibration. Calibration curves using standards between 0 and 100 μg L−1 gave a good linearity with correlation coefficient values ranging from 0.998 to 0.9997 for Cd, from 0.998 to 0.9998 for Hg and from 0.9996 to 0.9999 for Pb (N = 8). The repeatability of the method has been evaluated at 3 and 50 μg L−1 obtaining coefficients of variation between 2 and 5% (n = 6). The limit of detection values ranged from 0.15 to 0.20 μg L−1 for Cd, from 0.42 to 0.73 μg L−1 for Hg and from 0.23 to 0.39 μg L−1 for Pb. These values satisfy the threshold limit (3.4 μg L−1 for Cd, 10.0 μg L−1 for Hg and 85.0 μg L−1 for Pb) established by the Ministry of Labour and Social Affairs (Spain) for normal content of these metals in human urine and by the World Health Organization for normal mercury content in urine (i.e., 10 μg L−1). Finally, three urine samples were used to assess the applicability of the developed procedure. Recovery values ranged between 87 and 107% showing negligible matrix effects.
Patrocinador/es: The authors would like to thank the Spanish Ministry of Science and Innovation (project n. CTQ2011-23968) and the Spanish Ministry of Economy and Competitiveness and European Union (FEDER funds) (project no. CTQ2016-79991 R) for the financial support, and Agilent Technologies Inc. for the loan of the ICPOES spectrometer. P. Baile also thanks the Ministry of Education for her FPU grant (FPU14/04589).
URI: http://hdl.handle.net/10045/75095
ISSN: 0267-9477 (Print) | 1364-5544 (Online)
DOI: 10.1039/C7JA00366H
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © The Royal Society of Chemistry 2018
Revisión científica: si
Versión del editor: https://doi.org/10.1039/C7JA00366H
Aparece en las colecciones:INV - SP-BG - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Baile_etal_JAnalAtSpectrom_final.pdfVersión final (acceso restringido)486,44 kBAdobe PDFAbrir    Solicitar una copia
Thumbnail2018_Baile_etal_JAnalAtSpectrom_preprint.pdfPreprint (acceso abierto)1,51 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.