Effectiveness of a programme to reduce the burden of catheter-related bloodstream infections in a tertiary hospital

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/63052
Información del item - Informació de l'item - Item information
Title: Effectiveness of a programme to reduce the burden of catheter-related bloodstream infections in a tertiary hospital
Authors: Martínez-Morel, Héctor R. | Sánchez-Payá, José | García-Shimizu, P. | Mendoza-García, José Luis | Tenza-Iglesias, Isidra | Rodríguez-Díaz, J.C. | Merino-De-Lucas, E. | Nolasco, Andreu
Research Group/s: Grupo Balmis de Investigación en Salud Comunitaria e Historia de la Ciencia
Center, Department or Service: Universidad de Alicante. Departamento de Enfermería Comunitaria, Medicina Preventiva y Salud Pública e Historia de la Ciencia
Keywords: Catheter-related bloodstream infection | Central venous catheter | Prevention | Programme evaluation
Knowledge Area: Enfermería
Issue Date: Jul-2016
Publisher: Cambridge University Press
Citation: Epidemiology & Infection. 2016, 144(9): 2011-2017. doi:10.1017/S0950268815003313
Abstract: The objective of this study was to assess the effectiveness of a catheter-related bloodstream infection (CR BSI) reduction programme and healthcare workers' compliance with recommendations. A 3-year surveillance programme of CR BSIs in all hospital settings was implemented. As part of the programme, there was a direct observation of insertion and maintenance of central venous catheters (CVCs) to determine performance. A total of 38 education courses were held over the study period and feedback reports with the results of surveillance and recommendations were delivered to healthcare workers every 6 months. A total of 6722 short-term CVCs were inserted in 4982 patients for 58 763 catheter-days. Improvements of compliance with hand hygiene was verified at the insertion (87·1–100%, P < 0·001) and maintenance (51·1–72·1%, P = 0·029) of CVCs; and the use of chlorhexidine for skin disinfection was implemented at insertion (35·7–65·4%, P < 0·001) and maintenance (33·3–45·9%, P < 0·197) of CVCs. There were 266 CR BSI incidents recorded with an annual incidence density of 5·75/1000 catheter-days in the first year, 4·38 in the second year [rate ratio (RR) 0·76, 95% confidence interval (CI) 0·57–1·01] and 3·46 in the third year (RR 0·60, 95% CI 0·44–0·81). The education programme clearly improved compliance with recommendations for CVC handling, and was effective in reducing the burden of CR BSIs.
Sponsor: The programme was supported by the Carlos III Health Institute, Ministry of Science and Innovation of Spain (grant no. PI080881). Additional support was provided by the Foundation for Research of the General University Hospital of Alicante, Spain (grant nos. PC-06/2009, C-07/2010, C-04/2011).
URI: http://hdl.handle.net/10045/63052
ISSN: 0950-2688 (Print) | 1469-4409 (Online)
DOI: 10.1017/S0950268815003313
Language: eng
Type: info:eu-repo/semantics/article
Rights: © Cambridge University Press 2016
Peer Review: si
Publisher version: http://dx.doi.org/10.1017/S0950268815003313
Appears in Collections:INV - SALUD - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2016_Martinez-Morel_etal_EpidemiolInfect_final.pdfVersión final (acceso restringido)94,11 kBAdobe PDFOpen    Request a copy


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.