Parametric Study of the Errors Obtained from the Measurement of the Oscillating Movement of a Bridge Using Image Processing
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/62953
Títol: | Parametric Study of the Errors Obtained from the Measurement of the Oscillating Movement of a Bridge Using Image Processing |
---|---|
Autors: | Ferrer, Belén | Mas, David | García Santos, Juan Ignacio | Luzi, Guido |
Grups d'investigació o GITE: | Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES) | Óptica y Ciencias de la Visión |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Ingeniería Civil | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologías |
Paraules clau: | Displacement measurement | Long distance vibrometry | Image processing | Bridges | Radar interferometry |
Àrees de coneixement: | Mecánica de Medios Continuos y Teoría de Estructuras | Óptica |
Data de publicació: | de desembre-2016 |
Editor: | Springer Science+Business Media New York |
Citació bibliogràfica: | Journal of Nondestructive Evaluation. 2016, 35:53. doi:10.1007/s10921-016-0372-6 |
Resum: | The movement of a pedestrian bridge retrieved by means of image processing technique has been analysed in this paper. An optical target has been attached to the deck and its oscillation has been tracked with fast cameras. The movement of the bridge has also been measured with a radar interferometer and this result has been taken as the reference signal. Using these data, a parametric study of the errors introduced by the image-based methods has been performed. The influence of some variables in the measurement error such as the distance to the target, the image size, the type of camera or the movement amplitude has been analysed for four different distances, and two types of excitations. Results show that the relative error decreases with the amplitude and the target diameter and it increases with the target distance. Additionally, the maximum relative error obtained in most of the analysed cases is below 10 %. |
Patrocinadors: | The authors acknowledge the support of the Generalitat Valenciana through the project PROMETEO II/2015/015 and GV/2015/116 and the University of Alicante through the project GRE13-10. |
URI: | http://hdl.handle.net/10045/62953 |
ISSN: | 0195-9298 (Print) | 1573-4862 (Online) |
DOI: | 10.1007/s10921-016-0372-6 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © Springer Science+Business Media New York 2016. The final publication is available at Springer via http://dx.doi.org/10.1007/s10921-016-0372-6 |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1007/s10921-016-0372-6 |
Apareix a la col·lecció: | INV - GRESMES - Artículos de Revistas INV - IMAOS+V - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
2016_Ferrer_etal_JNondestructEval_final.pdf | Versión final (acceso restringido) | 1,76 MB | Adobe PDF | Obrir Sol·licitar una còpia |
2016_Ferrer_etal_JNondestructEval_preprint.pdf | Preprint (acceso abierto) | 4,02 MB | Adobe PDF | Obrir Vista prèvia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.