A reliable and valid questionnaire was developed to measure computer vision syndrome at the workplace

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/46652
Información del item - Informació de l'item - Item information
Títol: A reliable and valid questionnaire was developed to measure computer vision syndrome at the workplace
Autors: Seguí-Crespo, Mar | Cabrero-García, Julio | Crespo, Ana | Verdú, José | Ronda-Pérez, Elena
Grups d'investigació o GITE: Salud Pública | Calidad de Vida, Bienestar Psicológico y Salud | Grupo Balmis de Investigación en Salud Comunitaria e Historia de la Ciencia
Centre, Departament o Servei: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Departamento de Enfermería | Universidad de Alicante. Departamento de Enfermería Comunitaria, Medicina Preventiva y Salud Pública e Historia de la Ciencia
Paraules clau: Asthenopia | Computer terminals | Occupational health | Occupational exposure | Eye diseases | Diagnosis
Àrees de coneixement: Óptica | Enfermería | Medicina Preventiva y Salud Pública
Data de publicació: de juny-2015
Editor: Elsevier
Citació bibliogràfica: Journal of Clinical Epidemiology. 2015, 68(6): 662-673. doi:10.1016/j.jclinepi.2015.01.015
Resum: Objectives: To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Study Design and Setting: Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Testeretest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen’s kappa (k). Results: The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good testeretest repeatability both for the scores obtained [ICC 5 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (k 5 0.612; 95% CI: 0.384, 0.839). Conclusion: The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research.
Patrocinadors: This study was supported by the Spanish National Institute for Occupational Safety and Health (INSHT) (Grant number: 07/606). Project reference: UAL/PVDVIS.
URI: http://hdl.handle.net/10045/46652
ISSN: 0895-4356 (Print) | 1878-5921 (Online)
DOI: 10.1016/j.jclinepi.2015.01.015
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © 2015 Elsevier Inc.
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.jclinepi.2015.01.015
Apareix a la col·lecció: INV - SP - Artículos de Revistas
INV - SALUD - Artículos de Revistas
INV - CV, BP Y S - Artículos de Revistas
INV - WINTER HERIDAS - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2015_Segui_etal_JCE_final.pdfVersión final (acceso restringido)790,18 kBAdobe PDFObrir     Sol·licitar una còpia
Thumbnail2015_Segui_etal_JCE_accepted.pdfAccepted Manuscript (acceso abierto)2,17 MBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.