Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/39223
Información del item - Informació de l'item - Item information
Title: Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system
Authors: Montalbán, Raúl | Alió, Jorge L. | Javaloy, Jaime | Piñero, David P.
Research Group/s: Grupo de Óptica y Percepción Visual (GOPV)
Center, Department or Service: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Keywords: Keratoconus eyes | Intrasubject repeatability | Scheimpflug-photography | Placido-disk technology | Topography system
Knowledge Area: Óptica
Issue Date: Feb-2013
Publisher: Elsevier
Citation: Journal of Cataract & Refractive Surgery. 2013, 39(2): 211-218. doi:10.1016/j.jcrs.2012.10.033
Abstract: Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.
URI: http://hdl.handle.net/10045/39223
ISSN: 0886-3350 (Print) | 1873-4502 (Online)
DOI: 10.1016/j.jcrs.2012.10.033
Language: eng
Type: info:eu-repo/semantics/article
Rights: © 2012 ASCRS and ESCRS Published by Elsevier Inc.
Peer Review: si
Publisher version: http://dx.doi.org/10.1016/j.jcrs.2012.10.033
Appears in Collections:INV - GOPV - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2013_Montalban_etal_JCRS_final.pdfVersión final (acceso restringido)108,15 kBAdobe PDFOpen    Request a copy


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.