Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/39223
Información del item - Informació de l'item - Item information
Título: Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography–based system
Autor/es: Montalbán, Raúl | Alió, Jorge L. | Javaloy, Jaime | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Keratoconus eyes | Intrasubject repeatability | Scheimpflug-photography | Placido-disk technology | Topography system
Área/s de conocimiento: Óptica
Fecha de publicación: feb-2013
Editor: Elsevier
Cita bibliográfica: Journal of Cataract & Refractive Surgery. 2013, 39(2): 211-218. doi:10.1016/j.jcrs.2012.10.033
Resumen: Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.
URI: http://hdl.handle.net/10045/39223
ISSN: 0886-3350 (Print) | 1873-4502 (Online)
DOI: 10.1016/j.jcrs.2012.10.033
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2012 ASCRS and ESCRS Published by Elsevier Inc.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.jcrs.2012.10.033
Aparece en las colecciones:INV - GOPV - Artículos de Revistas