Evaluation of several pneumatic micronebulizers with different designs for use in ICP–AES and ICP–MS. Future directions for further improvement

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/2750
Información del item - Informació de l'item - Item information
Títol: Evaluation of several pneumatic micronebulizers with different designs for use in ICP–AES and ICP–MS. Future directions for further improvement
Autors: Maestre, Salvador E. | Todolí Torró, José Luis | Mermet, Jean Michel
Grups d'investigació o GITE: Análisis Químico Aplicado | Análisis de Alimentos
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Laboratoire des Sciences et Stratégies Analytiques
Paraules clau: ICP–AES | ICP–MS | Pneumatic micronebulizers | Food analysis | Liquid prefilming
Àrees de coneixement: Química Analítica
Data de publicació: de juliol-2004
Editor: Springer
Citació bibliogràfica: MAESTRE PÉREZ, Salvador; TODOLÍ TORRÓ, José Luis; MERMET, Jean Michel. “Evaluation of several pneumatic micronebulizers with different designs for use in ICP–AES and ICP–MS. Future directions for further improvement”. Analytical and Bioanalytical Chemistry. Vol. 379, No. 5-6 (July 2004). ISSN 1618-2642, pp. 888-899
Resum: This paper reports characterization of the behavior of five pneumatic micronebulizers based on slightly different designs in inductively coupled plasma atomic-emission spectrometry and mass spectrometry (ICP–AES and ICP–MS). Two nebulizers were used as reference nebulizers, a high-efficiency nebulizer (HEN) and a micromist (MM). They were compared with a commercially available PFA (tetrafluoroethylene–per- fluoroalkyl vinyl ether copolymer) nebulizer and with two new prototypes called the polymeric pneumatic concentric nebulizer (PMN) and the high-solids micronebulizer (HSM). The dimensions of the nebulizers, the gas back-pressure, and the free liquid uptake rates were measured. The study also included tertiary aerosol dropsize distributions, analyte transport rate, and analytical figures of merit, i.e. sensitivities and limits of detection, both in ICP–AES and ICP–MS. Recoveries for two food solid reference materials were also determined. Overall, the results indicated that the PFA and the HEN nebulizers provided the best results. These two nebulizers delivered a higher mass of analyte to the plasma and showed better sensitivies giving lower limits of detection than the PMN, HSM and MM. The results revealed that the liquid prefilming effect occurring before aerosol production in the PFA nebulizer promoted more effi- cient interaction of liquid and gas, thus affording good results even though gas back-pressure values could be maintained below 3 bar. In contrast, the HEN had to be operated at about 7 bar under the same conditions. Nebulizer design did not have a relevant effect on the recovery, which confirmed that the spray chamber plays an important role in terms of non-spectroscopic interferences.
URI: http://hdl.handle.net/10045/2750
ISSN: 1618-2642 | 1618-2650
DOI: 10.1007/s00216-004-2664-4
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: The original publication is available at www.springerlink.com
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1007/s00216-004-2664-4
Apareix a la col·lecció: INV - AQA-CCA - Artículos de Revistas
INV - NANOBIOPOL - Artículos de Revistas
INV - AAQCN - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
ThumbnailABC 379 2004 888.pdf1,82 MBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.