Evaluation of several pneumatic micronebulizers with different designs for use in ICP–AES and ICP–MS. Future directions for further improvement

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/2750
Registre complet
Registre complet
Camp Dublin Core Valor Idioma
dc.contributorAnálisis Químico Aplicadoen
dc.contributorAnálisis de Alimentosen
dc.contributor.authorMaestre, Salvador E.-
dc.contributor.authorTodolí Torró, José Luis-
dc.contributor.authorMermet, Jean Michel-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaen
dc.contributor.otherLaboratoire des Sciences et Stratégies Analytiques-
dc.date.accessioned2007-11-03T17:45:03Z-
dc.date.available2007-11-03T17:45:03Z-
dc.date.issued2004-07-
dc.identifier.citationMAESTRE PÉREZ, Salvador; TODOLÍ TORRÓ, José Luis; MERMET, Jean Michel. “Evaluation of several pneumatic micronebulizers with different designs for use in ICP–AES and ICP–MS. Future directions for further improvement”. Analytical and Bioanalytical Chemistry. Vol. 379, No. 5-6 (July 2004). ISSN 1618-2642, pp. 888-899en
dc.identifier.issn1618-2642-
dc.identifier.issn1618-2650-
dc.identifier.urihttp://hdl.handle.net/10045/2750-
dc.description.abstractThis paper reports characterization of the behavior of five pneumatic micronebulizers based on slightly different designs in inductively coupled plasma atomic-emission spectrometry and mass spectrometry (ICP–AES and ICP–MS). Two nebulizers were used as reference nebulizers, a high-efficiency nebulizer (HEN) and a micromist (MM). They were compared with a commercially available PFA (tetrafluoroethylene–per- fluoroalkyl vinyl ether copolymer) nebulizer and with two new prototypes called the polymeric pneumatic concentric nebulizer (PMN) and the high-solids micronebulizer (HSM). The dimensions of the nebulizers, the gas back-pressure, and the free liquid uptake rates were measured. The study also included tertiary aerosol dropsize distributions, analyte transport rate, and analytical figures of merit, i.e. sensitivities and limits of detection, both in ICP–AES and ICP–MS. Recoveries for two food solid reference materials were also determined. Overall, the results indicated that the PFA and the HEN nebulizers provided the best results. These two nebulizers delivered a higher mass of analyte to the plasma and showed better sensitivies giving lower limits of detection than the PMN, HSM and MM. The results revealed that the liquid prefilming effect occurring before aerosol production in the PFA nebulizer promoted more effi- cient interaction of liquid and gas, thus affording good results even though gas back-pressure values could be maintained below 3 bar. In contrast, the HEN had to be operated at about 7 bar under the same conditions. Nebulizer design did not have a relevant effect on the recovery, which confirmed that the spray chamber plays an important role in terms of non-spectroscopic interferences.en
dc.languageengen
dc.publisherSpringeren
dc.rightsThe original publication is available at www.springerlink.comen
dc.subjectICP–AESen
dc.subjectICP–MSen
dc.subjectPneumatic micronebulizersen
dc.subjectFood analysisen
dc.subjectLiquid prefilmingen
dc.subject.otherQuímica Analíticaen
dc.titleEvaluation of several pneumatic micronebulizers with different designs for use in ICP–AES and ICP–MS. Future directions for further improvementen
dc.typeinfo:eu-repo/semantics/articleen
dc.peerreviewedsien
dc.identifier.doi10.1007/s00216-004-2664-4-
dc.relation.publisherversionhttp://dx.doi.org/10.1007/s00216-004-2664-4-
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess-
Apareix a la col·lecció: INV - AQA-CCA - Artículos de Revistas
INV - NANOBIOPOL - Artículos de Revistas
INV - AAQCN - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
ThumbnailABC 379 2004 888.pdf1,82 MBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.