A new approach for the determination of anaerobic threshold: methodological survey on the modified Dmax method

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/23626
Información del item - Informació de l'item - Item information
Títol: A new approach for the determination of anaerobic threshold: methodological survey on the modified Dmax method
Autors: Siahkouhian, Marefat | Azizan, Shabnam | Roohi, Babak Nakhostin
Paraules clau: PSLS mathematical model | Narita equation | Heart Rate Deflection Point (HRDP)
Àrees de coneixement: Educación Física y Deportiva
Data de publicació: de juliol-2012
Editor: Universidad de Alicante. Área de Educación Física y Deporte
Citació bibliogràfica: SIAHKOUHIAN, Marefat; AZIZAN, Shabnam; ROOHI, Babak Nakhostin. “A new approach for the determination of anaerobic threshold: methodological survey on the modified Dmax method”. Journal of Human Sport and Exercise [en línea]. Vol. 7, No. 2 (2012). ISSN 1988-5202, pp. 599-607. http://www.jhse.ua.es/jhse/article/view/368 [consulta: 25 julio 2012]
Resum: A wide variety of diagnostic techniques can be found in the literature for anaerobic threshold (AT) assessment. The aim of this study was to investigate if the heart rate (HR) at the modified Dmax method (Mod-Dmax) using parallel straight line slope (PSLS) mathematical model and the Narita target heart rate equation was comparable with the HR measured at the AT by the continuous respiratory gas measurements in healthy young girls. Eight (age 19.29±1.70 years) healthy young girls performed an exhaustive treadmill exercise test for determination of the HR at Mod-Dmax using PSLS model and Narita equation. The AT of the participants was also calculated by the continuous respiratory gas measurements according to the Craig method. There was no significant difference between the HR determined at the Mod-Dmax method and the HR measured at the AT by the continuous respiratory gas measurements (167±9.22 vs. 165.25±6.32 b/min). Bland and Altman plots revealed a good agreement between the determined HR at Mod-Dmax and values of the HR measured at the AT by the continuous respiratory gas measurements (95% CI =−20 to+22.8 b/min). According to the results, the Mod-Dmax using PSLS model and the Narita equation during the exhaustive treadmill exercise test is an accurate and reliable noninvasive alternative to the cumbersome, expensive, and time-consuming invasive methods. Therefore, the Mod-Dmax method can be used for the determination of AT in healthy young girls.
URI: http://hdl.handle.net/10045/23626
ISSN: 1988-5202
DOI: 10.4100/jhse.2012.72.23
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: Licencia Creative Commons Reconocimiento-NoComercial-SinObraDerivada 3.0
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.4100/jhse.2012.72.23
Apareix a la col·lecció: Journal of Human Sport and Exercise - 2012, Vol. 7, No. 2

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnailjhse_Vol_VII_N_II_599-607.pdf278,01 kBAdobe PDFObrir Vista prèvia


Aquest ítem està subjecte a una llicència de Creative Commons Llicència Creative Commons Creative Commons