Non-destructive evaluation of the effects of exposure environment in mortars using non-linear ultrasonic measurements

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/132671
Información del item - Informació de l'item - Item information
Title: Non-destructive evaluation of the effects of exposure environment in mortars using non-linear ultrasonic measurements
Authors: Ortega, José Marcos | Miró, Marina | Ibáñez Gosálvez, Javier Francisco | Tenza-Abril, Antonio José
Research Group/s: Durabilidad de Materiales y Construcciones en Ingeniería y Arquitectura | Tecnología de Materiales y Territorio (TECMATER)
Center, Department or Service: Universidad de Alicante. Departamento de Ingeniería Civil | Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal
Keywords: Non-linear ultrasonic test | Non-destructive characterization | Real environment | Non-optimum condition | Microstructure
Issue Date: 6-Mar-2023
Publisher: Elsevier
Citation: Developments in the Built Environment. 2023, 14: 100142. https://doi.org/10.1016/j.dibe.2023.100142
Abstract: The development of non-destructive techniques has currently a high interest, such as those based on non-linear ultrasonic measurements. In this work it has been assessed the possible application of non-linear ultrasonic measurements for getting information related to the microstructure and properties of Portland cement mortars exposed to real and non-optimum environments. The pore structure was studied using mercury intrusion porosimetry and differential thermal analyses. Mechanical strengths and linear ultrasonic pulse velocity were determined. Regarding non-linear ultrasonic measurements, the results of parameters R and DIFA were analyzed. The tests were performed at 28 and 250 days. At later ages, a loss of microstructure refinement and a worsening of mechanical performance of the mortars were observed. The results of non-linear ultrasonic parameters R and DIFA overall agreed with those obtained for the microstructural and mechanical characterization performed. In particular, an adequate correlation between parameter DIFA and the pore size distributions was observed.
Sponsor: This research has been financially supported by the Conselleria de Educación, Investigación, Cultura y Deporte (currently re-named as Conselleria de Innovación, Universidades, Ciencia y Sociedad Digital) of Generalitat Valenciana (Spain) through the project code GV/2019/070 and by the Ministerio de Ciencia e Innovación of Spain through the project code RTC2019-006964-3. Part of the results presented in this manuscript was obtained in the PhD thesis carried out by Javier Ibáñez-Gosálvez at University of Alicante (Spain). Authors express their gratitude to Cementos Portland Valderrivas S.A. for supplying the Portland cement CEM I 42.5 R used in this work.
URI: http://hdl.handle.net/10045/132671
ISSN: 2666-1659
DOI: 10.1016/j.dibe.2023.100142
Language: eng
Type: info:eu-repo/semantics/article
Rights: © 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Peer Review: si
Publisher version: https://doi.org/10.1016/j.dibe.2023.100142
Appears in Collections:INV - TECMATER - Artículos de Revistas
INV - DMCIA - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailOrtega_etal_2023_DevelopBuiltEnviron.pdf1,22 MBAdobe PDFOpen Preview


This item is licensed under a Creative Commons License Creative Commons