Optimization of a holographic memory setup using an LCD and a PVA-based photopolymer

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/12017
Información del item - Informació de l'item - Item information
Títol: Optimization of a holographic memory setup using an LCD and a PVA-based photopolymer
Autors: Fernandez-Varo, Helena | Ortuño, Manuel | Gallego, Sergi | Márquez, Andrés | García Llopis, Celia | Fuentes Rosillo, Rosa | Beléndez, Augusto | Pascual, Inmaculada
Grups d'investigació o GITE: Holografía y Procesado Óptico
Centre, Departament o Servei: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal
Paraules clau: Holography | Holographic recording materials | Holographic memories | Photopolymers | Liquid crystal displays | Volume holograms
Àrees de coneixement: Óptica | Física Aplicada
Data de creació: 25-de gener-2008
Data de publicació: de gener-2010
Editor: Elsevier
Citació bibliogràfica: FERNÁNDEZ VARÓ, Elena, et al. "Optimization of a holographic memory setup using an LCD and a PVA-based photopolymer". Optik. Vol. 121, No. 2 (2010). ISSN 0030-4026, pp. 151-158
Resum: Holographic data pages were stored in a polyvinyl alcohol (PVA)/acrylamide (AA) photopolymer. This material is formed of AA photopolymers which are considered interesting materials for recording holographic memories. A liquid crystal device was used to modify the object beam and store the data pages in the material. During the storage process, some parameters like exposure time, beam ratio and reading beam intensity were controlled to obtain high image quality after the reconstruction process. The bit error rate (BER) was calculated fitting the histograms of the images to determine what parameters improve the quality of the images.
Patrocinadors: This work was supported by the Ministerio de Educación y Ciencia (Spain) under projects FIS2005-05881-C02-01 and FIS2005-05881-C02-02.
URI: http://hdl.handle.net/10045/12017
ISSN: 0030-4026
DOI: 10.1016/j.ijleo.2008.05.031
Idioma: eng
Tipus: info:eu-repo/semantics/article
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.ijleo.2008.05.031
Apareix a la col·lecció: INV - GHPO - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
ThumbnailOPTIK_2009proofs.pdfVersión revisada (acceso libre)128,16 kBAdobe PDFObrir Vista prèvia
ThumbnailOptik_v121_n2_p151_2020.pdfVersión final (acceso restringido)1,17 MBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.