Optimization of a holographic memory setup using an LCD and a PVA-based photopolymer
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/12017
Títol: | Optimization of a holographic memory setup using an LCD and a PVA-based photopolymer |
---|---|
Autors: | Fernandez-Varo, Helena | Ortuño, Manuel | Gallego, Sergi | Márquez, Andrés | García Llopis, Celia | Fuentes Rosillo, Rosa | Beléndez, Augusto | Pascual, Inmaculada |
Grups d'investigació o GITE: | Holografía y Procesado Óptico |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal |
Paraules clau: | Holography | Holographic recording materials | Holographic memories | Photopolymers | Liquid crystal displays | Volume holograms |
Àrees de coneixement: | Óptica | Física Aplicada |
Data de creació: | 25-de gener-2008 |
Data de publicació: | de gener-2010 |
Editor: | Elsevier |
Citació bibliogràfica: | FERNÁNDEZ VARÓ, Elena, et al. "Optimization of a holographic memory setup using an LCD and a PVA-based photopolymer". Optik. Vol. 121, No. 2 (2010). ISSN 0030-4026, pp. 151-158 |
Resum: | Holographic data pages were stored in a polyvinyl alcohol (PVA)/acrylamide (AA) photopolymer. This material is formed of AA photopolymers which are considered interesting materials for recording holographic memories. A liquid crystal device was used to modify the object beam and store the data pages in the material. During the storage process, some parameters like exposure time, beam ratio and reading beam intensity were controlled to obtain high image quality after the reconstruction process. The bit error rate (BER) was calculated fitting the histograms of the images to determine what parameters improve the quality of the images. |
Patrocinadors: | This work was supported by the Ministerio de Educación y Ciencia (Spain) under projects FIS2005-05881-C02-01 and FIS2005-05881-C02-02. |
URI: | http://hdl.handle.net/10045/12017 |
ISSN: | 0030-4026 |
DOI: | 10.1016/j.ijleo.2008.05.031 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1016/j.ijleo.2008.05.031 |
Apareix a la col·lecció: | INV - GHPO - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
OPTIK_2009proofs.pdf | Versión revisada (acceso libre) | 128,16 kB | Adobe PDF | Obrir Vista prèvia |
Optik_v121_n2_p151_2020.pdf | Versión final (acceso restringido) | 1,17 MB | Adobe PDF | Obrir Sol·licitar una còpia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.