Evaluation of electrosprayed graphene oxide coatings for elemental analysis by thin film microextraction followed by Laser-induced Breakdown Spectroscopy detection

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/117294
Información del item - Informació de l'item - Item information
Title: Evaluation of electrosprayed graphene oxide coatings for elemental analysis by thin film microextraction followed by Laser-induced Breakdown Spectroscopy detection
Authors: Ripoll-Seguer, Laura | Legnaioli, Stefano | Palleschi, Vincenzo | Hidalgo, Montserrat
Research Group/s: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Center, Department or Service: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Keywords: LIBS | Electrospray deposition | Graphene oxide | Thin film microextraction | Liquid samples analysis
Knowledge Area: Química Analítica
Issue Date: Sep-2021
Publisher: Elsevier
Citation: Spectrochimica Acta Part B: Atomic Spectroscopy. 2021, 183: 106267. https://doi.org/10.1016/j.sab.2021.106267
Abstract: In this work, a solid phase microextraction procedure, denoted as Thin Film Microextraction (TFME), was combined with Laser-induced Breakdown Spectroscopy for the detection of several analytes in aqueous solutions (Cu, Cr, Ni and Pb). The adsorbent films, consisting of a thin layer of graphene oxide deposited on glass substrates, were generated by using the electrospray deposition technique (ESD). Several parameters affecting the quality and shape of the films resulting from the ESD process were studied, and the morphology and adsorption capacity of the films were evaluated. The generated films were used for extraction of the target analytes from aqueous solutions and, after extraction, the analytes-enriched adsorbents were analysed by LIBS without the need of any desorption or elution step. In order to assess the analytical capability of the TFME-LIBS procedure, different analytical figures of merit of the proposed TFME-LIBS methodology were evaluated. The obtained limits of detection were 14 μg kg−1 for Pb and 15 μg kg−1 for the rest of the tested analytes. Measurement repeatability was better than 4% RSD at low concentration level (20 μg kg−1) but deteriorated by increasing the concentration level at 100 μg kg−1, with %RSD ranging from 3.6% (Cr) to 24% (Pb). Method trueness, evaluated from the analysis of a real sample of bottled water, led to recovery values in the range 85%–106%.
Sponsor: This work was supported by the Spanish Ministry of Economy and Competitiveness [CTQ2016-79991-R], the Regional Government of Valencia (Spain) [PROMETEO/2013/038 and PROMETEO/2018/087]; and the University of Alicante [UAUSTI17-04 and UAUSTI18-04]. L. Ripoll is grateful to the Ministry of Economy and Competitiveness for her PhD fellowship (FPI-MICINN (BES-2012-058759)).
URI: http://hdl.handle.net/10045/117294
ISSN: 0584-8547 (Print) | 1873-3565 (Online)
DOI: 10.1016/j.sab.2021.106267
Language: eng
Type: info:eu-repo/semantics/article
Rights: © 2021 Published by Elsevier B.V.
Peer Review: si
Publisher version: https://doi.org/10.1016/j.sab.2021.106267
Appears in Collections:INV - SP-BG - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailRipoll_etal_2021_SpectrochimActaPartB_final.pdfVersión final (acceso restringido)6,79 MBAdobe PDFOpen    Request a copy
ThumbnailRipoll_etal_2021_SpectrochimActaPartB_accepted.pdfAccepted Manuscript (acceso abierto)1,73 MBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.