Analytical performance of the Conical torch in inductively coupled plasma optical emission spectroscopy operating methanol and 1-propanol solutions

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/110776
Información del item - Informació de l'item - Item information
Title: Analytical performance of the Conical torch in inductively coupled plasma optical emission spectroscopy operating methanol and 1-propanol solutions
Authors: Grindlay, Guillermo | Alavi, Sina | Mostaghimi, Javad
Research Group/s: Espectrometría Atómica Analítica (GEAA)
Center, Department or Service: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Keywords: Conical torch | Matrix effects | Methanol | 1-propanol | Inductively coupled plasma | Optical emission spectrometry
Knowledge Area: Química Analítica
Issue Date: 14-Oct-2020
Publisher: Royal Society of Chemistry
Citation: Journal of Analytical Atomic Spectrometry. 2020, 35: 2956-2963. https://doi.org/10.1039/D0JA00368A
Abstract: This work explores, for the first time, the strengths and weaknesses of the Conical torch in ICP-OES operating methanol and 1-propanol solutions ranging from 30% to 100% w w−1. To this end, Conical torch performance has been evaluated considering: (i) plasma fundamental properties; (ii) plasma robustness; (iii) carbon-based background emission; and (iv) analytical figures of merit. For the sake of comparison, a Fassel torch has been employed as a reference. Results show that the discharge for the Conical torch is highly robust and plasma characteristics (i.e., excitation temperature and electron number density) are mostly unaffected by the introduction of pure and hydroalcoholic solutions of methanol and 1-propanol. In contrast, the discharge for the Fassel torch is severely affected by organics introduction and it is not feasible to operate methanol solutions above 30% w w−1. Because torch geometry and improved gas flow patterns, the Conical torch affords higher emission signal (2-fold) than the Fassel torch. Nevertheless, the detection limits for both torches are comparable, which is due to the increase in both (carbon-based) background emission and signal noise for the Conical torch. From these results and considering that the Conical torch requires less r.f. power (35%) and argon consumption (55%) than the Fassel one, it is beyond doubt that the former torch is more advantageous for those applications requiring the analysis of alcohol solutions (i.e. extraction procedures and chromatographic separations).
Sponsor: Financial support of Natural Sciences and Engineering Research Council (NSERC) of Canada and Dean's Strategic Fund by the University of Toronto are gratefully acknowledged. Guillermo Grindlay would like to thank the University of Alicante (ACIE19-05) for the financial support for this work.
URI: http://hdl.handle.net/10045/110776
ISSN: 0267-9477 (Print) | 1364-5544 (Online)
DOI: 10.1039/D0JA00368A
Language: eng
Type: info:eu-repo/semantics/article
Rights: © The Royal Society of Chemistry 2020
Peer Review: si
Publisher version: https://doi.org/10.1039/D0JA00368A
Appears in Collections:INV - GEAA - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
ThumbnailGrindlay_etal_2020_JAnalAtSpectrom_final.pdfVersión final (acceso restringido)852,25 kBAdobe PDFOpen    Request a copy
ThumbnailGrindlay_etal_2020_JAnalAtSpectrom_accepted.pdfAccepted Manuscript (acceso abierto)1,86 MBAdobe PDFOpen Preview