Electrospray deposition followed by laser-induced breakdown spectroscopy (ESD-LIBS): a new method for trace elemental analysis of aqueous samples

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/97171
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorEspectroscopía Atómica-Masas y Química Analítica en Condiciones Extremases_ES
dc.contributor.authorRipoll-Seguer, Laura-
dc.contributor.authorHidalgo, Montserrat-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaes_ES
dc.contributor.otherUniversidad de Alicante. Instituto Universitario de Materialeses_ES
dc.date.accessioned2019-10-07T12:29:52Z-
dc.date.available2019-10-07T12:29:52Z-
dc.date.issued2019-07-31-
dc.identifier.citationJournal of Analytical Atomic Spectrometry. 2019, 34: 2016-2026. doi:10.1039/C9JA00145Jes_ES
dc.identifier.issn0267-9477 (Print)-
dc.identifier.issn1364-5544 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/97171-
dc.description.abstractThe combination of electrospray deposition with laser-induced breakdown spectroscopy (ESD-LIBS) was investigated as a potential approach to the detection and quantification of Zn, Cd, Cr and Ni, at trace levels, in aqueous samples. In this analytical procedure, the aqueous samples were first converted into solids in an electrospray system. To this end, micro-volumes of liquids were electro-sprayed onto a heated substrate, leading to the generation of solid residues. Afterwards, the as-obtained residues were analysed by LIBS. Three calibration methodologies were tested with the proposed ESD-LIBS methodology, namely external calibration, conventional standard addition calibration and on-line standard addition calibration. In all cases, the analytical features of the ESD-LIBS method were assessed. The obtained limits of detection ranged from 9 μg kg−1 to 57 μg kg−1, depending on the element and on the calibration modality used. Method trueness, evaluated from the analysis of a real sample of tap water, was highly dependent on the calibration method. The use of external calibration led to recovery values in the range of 18–123%, indicating the existence of strong matrix effects. This drawback was overcome with the application of conventional standard addition and on-line standard addition calibration modalities, for which recovery values were improved to the ranges 91–110% and 90–105%, respectively. Among them, the use of on-line standard addition provides a sensitive and accurate methodology with possibilities of automation.es_ES
dc.description.sponsorshipL. Ripoll is grateful to the Ministry of Economy and Competitiveness for her PhD fellowship (FPI-MICINN (BES-2012-058759)).es_ES
dc.languageenges_ES
dc.publisherRoyal Society of Chemistryes_ES
dc.rights© The Royal Society of Chemistry 2019es_ES
dc.subjectLIBSes_ES
dc.subjectElectrospray depositiones_ES
dc.subjectLiquid sampleses_ES
dc.subjectTrace analysises_ES
dc.subject.otherQuímica Analíticaes_ES
dc.titleElectrospray deposition followed by laser-induced breakdown spectroscopy (ESD-LIBS): a new method for trace elemental analysis of aqueous sampleses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1039/C9JA00145J-
dc.relation.publisherversionhttps://doi.org/10.1039/C9JA00145Jes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//BES-2012-058759-
Aparece en las colecciones:INV - SP-BG - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2019_Ripoll_Hidalgo_JAnalAtSpectrom_final.pdfVersión final (acceso restringido)1,28 MBAdobe PDFAbrir    Solicitar una copia
Thumbnail2019_Ripoll_Hidalgo_JAnalAtSpectrom_accepted.pdfAccepted Manuscript (acceso abierto)1,45 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.