Títol: | MEM and Nott dynamic retinoscopy in patients with disorders of vergence and accommodation |
---|---|
Autors: | García-Muñoz, Ángel | Cacho-Martínez, Pilar |
Grups d'investigació o GITE: | Salud Pública |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Enfermería Comunitaria, Medicina Preventiva y Salud Pública e Historia de la Ciencia |
Paraules clau: | Accommodative lag | Accommodative lead | Accommodative response | Dynamic retinoscopy | General binocular dysfunction | Monocular estimate method | Nott retinoscopy |
Àrees de coneixement: | Medicina Preventiva y Salud Pública | Óptica |
Data de creació: | 10-de setembre-2001 |
Data de publicació: | de maig-2002 |
Editor: | The College of Optometrists | Blackwell Publishing |
Citació bibliogràfica: | GARCÍA MUÑOZ, Ángel; CACHO MARTÍNEZ, Pilar. "MEM and Nott dynamic retinoscopy in patients with disorders of vergence and accommodation". Ophthalmic and Physiological Optics. Vol. 22, Issue 3 (May 2002). ISSN 1040-5488, pp. 214-220 |
Resum: | The accommodative response in 34 patients with accommodative and binocular disorders was assessed with two different techniques of dynamic retinoscopy used in clinical practice: monocular estimate method (MEM) and Nott retinoscopy. The data obtained by both techniques were compared, evaluating the correlation and agreement between them. Results showed that there were statistically significant differences between the techniques with MEM values being more plus than Nott ones. There was a high correlation between the two techniques (0.90) and the regression analysis indicated that a linear relationship existed between MEM and Nott dynamic retinoscopy, so that accommodative lag value for Nott dynamic retinoscopy would be calculated by dividing the MEM result by 2. However, although both retinoscopies were related, there was a lack of agreement between them (±0.53 D) indicating that the two methods are not interchangeable for clinical purposes. |
URI: | http://hdl.handle.net/10045/9647 |
ISSN: | 0275-5408 (Print) | 1475-1313 (Online) |
DOI: | 10.1046/j.1475-1313.2002.00026.x |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | The definitive version is available at www.blackwell-synergy.com |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1046/j.1475-1313.2002.00026.x |