Differences in corneo-scleral topographic profile between healthy and keratoconus corneas

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/87467
Información del item - Informació de l'item - Item information
Título: Differences in corneo-scleral topographic profile between healthy and keratoconus corneas
Autor/es: Piñero, David P. | Martínez-Abad, Antonio | Soto-Negro, Roberto | Ruiz Fortes, Pedro | Pérez Cambrodí, Rafael J. | Ariza-Gracia, Miguel Á. | Carracedo, Gonzalo
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Keratoconus | Corneo-Scleral topography | Profilometry | Sagittal height
Área/s de conocimiento: Óptica
Fecha de publicación: feb-2019
Editor: Elsevier
Cita bibliográfica: Contact Lens and Anterior Eye. 2019, 42(1): 75-84. doi:10.1016/j.clae.2018.05.005
Resumen: Purpose: To evaluate the differences in corneo-scleral topographic profile between healthy and keratoconus eyes, and their potential diagnostic ability for keratoconus detection. Methods: Prospective comparative study including 21 keratoconic eyes (11 patients) and 88 healthy eyes (88 patients). In all cases, a complete eye exam was performed including an evaluation of the corneo-scleral profile. The diagnostic ability of corneo-scleral topographic parameters to detect keratoconus was evaluated using the receiver operating characteristic (ROC) curve. Results: A significant lower inferior tangent angle at limbus (ITA) was found in the keratoconic group compared to the control group (p = 0.024). Regarding sagittal heights, significant differences between groups were found in temporal sagittal height (TSH) for 11 mm (p = 0.040), 12 mm (p = 0.041) and 13 mm corneal chords (p = 0.040), difference between temporal and nasal sagittal heights (T-NSH) for 12 mm (p = 0.025) and 13 mm (p = 0.034), and maximum sagittal height (MaxSH) for 12 mm (p = 0.043), with higher values in keratoconus. In bilateral cases, these differences were not found when comparing with the least severe keratoconus eye. Statistical significance for the ROC curve was only found for ITA (p = 0.025), 12-mm (p = 0.048) and 13-mm TSH (p = 0.042), and 13-mm T-NSH (p = 0.037), with cutoff values associated to limited values of sensitivity and specificity. Conclusions: The corneo-scleral profile in keratoconus presents higher levels of asymmetry compared to healthy eyes, especially in eyes with moderate and advanced stages of the disease. The diagnostic accuracy of corneo-scleral topographic data alone for keratoconus detection is limited and must be used in conjunction with other clinical parameters.
URI: http://hdl.handle.net/10045/87467
ISSN: 1367-0484 (Print) | 1476-5411 (Online)
DOI: 10.1016/j.clae.2018.05.005
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2018 British Contact Lens Association. Published by Elsevier Ltd.
Revisión científica: si
Versión del editor: https://doi.org/10.1016/j.clae.2018.05.005
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2019_Pinero_etal_ContactLensAntEye_final.pdfVersión final (acceso restringido)1,89 MBAdobe PDFAbrir    Solicitar una copia
Thumbnail2019_Pinero_etal_ContactLensAntEye_preprint.pdfPreprint (acceso abierto)2,12 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.