A New Approach for the Calculation of Total Corneal Astigmatism Considering the Magnitude and Orientation of Posterior Corneal Astigmatism and Thickness

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/84034
Información del item - Informació de l'item - Item information
Título: A New Approach for the Calculation of Total Corneal Astigmatism Considering the Magnitude and Orientation of Posterior Corneal Astigmatism and Thickness
Autor/es: Piñero, David P. | Caballero, María T. | Nicolás Albujer, Juan Miguel | Fez Saiz, Dolores de | Camps, Vicente J.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Total corneal astigmatism | Gaussian optics | Keratometry | Power vectors | Keratometric astigmatism
Área/s de conocimiento: Óptica
Fecha de publicación: jun-2018
Editor: Wolters Kluwer Health
Cita bibliográfica: Cornea. 2018, 37(6): 720-726. doi:10.1097/ICO.0000000000001577
Resumen: Purpose: To evaluate a new method of calculation of total corneal astigmatism based on Gaussian optics and the power design of a spherocylindrical lens (C) in the healthy eye and to compare it with keratometric (K) and power vector (PV) methods. Methods: A total of 92 healthy eyes of 92 patients (age, 17–65 years) were enrolled. Corneal astigmatism was calculated in all cases using K, PV, and our new approach C that considers the contribution of corneal thickness. An evaluation of the interchangeability of our new approach with the other 2 methods was performed using Bland–Altman analysis. Results: Statistically significant differences between methods were found in the magnitude of astigmatism (P < 0.001), with the highest values provided by K. These differences in the magnitude of astigmatism were clinically relevant when K and C were compared [limits of agreement (LoA), −0.40 to 0.62 D), but not for the comparison between PV and C (LoA, −0.03 to 0.01 D). Differences in the axis of astigmatism between methods did not reach statistical significance (P = 0.408). However, they were clinically relevant when comparing K and C (LoA, −5.48 to 15.68 degrees) but not for the comparison between PV and C (LoA, −1.68 to 1.42 degrees). Conclusions: The use of our new approach for the calculation of total corneal astigmatism provides astigmatic results comparable to the PV method, which suggests that the effect of pachymetry on total corneal astigmatism is minimal in healthy eyes.
URI: http://hdl.handle.net/10045/84034
ISSN: 0277-3740 (Print) | 1536-4798 (Online)
DOI: 10.1097/ICO.0000000000001577
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2018 Wolters Kluwer Health, Inc.
Revisión científica: si
Versión del editor: https://doi.org/10.1097/ICO.0000000000001577
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Pinero_etal_Cornea_final.pdfVersión final (acceso restringido)332,14 kBAdobe PDFAbrir    Solicitar una copia
Thumbnail2018_Pinero_etal_Cornea_preprint.pdfPreprint (acceso abierto)2,1 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.