Dispersive micro solid-phase extraction (DµSPE) with graphene oxide as adsorbent for sensitive elemental analysis of aqueous samples by laser induced breakdown spectroscopy (LIBS)

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/79629
Información del item - Informació de l'item - Item information
Títol: Dispersive micro solid-phase extraction (DµSPE) with graphene oxide as adsorbent for sensitive elemental analysis of aqueous samples by laser induced breakdown spectroscopy (LIBS)
Autors: Ruiz-Espinar, Francisco Julián | Ripoll-Seguer, Laura | Hidalgo, Montserrat | Canals, Antonio
Grups d'investigació o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Paraules clau: Dispersive micro solid-phase extraction | Graphene oxide | LIBS | Trace analysis | Liquid samples
Àrees de coneixement: Química Analítica
Data de publicació: 1-de gener-2019
Editor: Elsevier
Citació bibliogràfica: Talanta. 2019, 191: 162-170. doi:10.1016/j.talanta.2018.08.044
Resum: In this work, the combination of dispersive micro solid-phase extraction (DµSPE) with laser-induced breakdown spectroscopy (LIBS) was evaluated for simultaneous preconcentration and detection of Zn, Cd, Mn, Ni, Cr and Pb in aqueous samples. Two adsorbent materials were tested in the microextraction step, namely graphene oxide and activated carbon. In both cases, the microextraction process consisted in the dispersion of a small quantity of adsorbent in the sample solution containing the analytes. However, while the use of activated carbon required a previous chelation of the metals, this step was avoided with the use of graphene oxide. After extraction, the analytes retained in the adsorbents were analysed by LIBS. Several experimental factors affecting the extraction of the metals (adsorbent amount, pH and extraction time) were optimized by means of the traditional univariate approach. Under optimum microextraction conditions, the analytical features of the proposed DµSPE-LIBS methods were assessed, leading to limits of detection below 100 µg kg−1 and 50 µg kg−1 with the use of activated carbon and graphene oxide, respectively, as adsorbents in the DµSPE process. Trueness evaluation of the most sensitive procedure was carried out by spike and recovery experiments in a real sample of tap water, leading to recovery values in the range 98–110%.
Patrocinadors: This work was supported by the Spanish Ministry of Economy and Competitiveness, (Spain) (Project no. CTQ2016-79991-R and fellowship number BES-2012-058759 (FPI-MICINN)); the Regional Government of Valencia (Spain) (Project no. PROMETEO/2013/038); and the University of Alicante, (Spain) (Grant no. UAUSTI16-04).
URI: http://hdl.handle.net/10045/79629
ISSN: 0039-9140 (Print) | 1873-3573 (Online)
DOI: 10.1016/j.talanta.2018.08.044
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © 2018 Elsevier B.V.
Revisió científica: si
Versió de l'editor: https://doi.org/10.1016/j.talanta.2018.08.044
Apareix a la col·lecció: INV - SP-BG - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2019_Ruiz_etal_Talanta_final.pdfVersión final (acceso restringido)1,33 MBAdobe PDFObrir     Sol·licitar una còpia
Thumbnail2019_Ruiz_etal_Talanta_accepted.pdfAccepted Manuscript (acceso abierto)1,58 MBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.