Inter-rater reliability of trained and untrained raters for measuring jump height with the MyJump app

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/77068
Información del item - Informació de l'item - Item information
Título: Inter-rater reliability of trained and untrained raters for measuring jump height with the MyJump app
Autor/es: Pueo, Basilio | Jimenez-Olmedo, Jose Manuel | Penichet-Tomás, Alfonso | Bernal-Soriano, Mari Carmen
Grupo/s de investigación o GITE: Research in Physical Education, Fitness and Performance (RIPEFAP)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Didáctica General y Didácticas Específicas
Palabras clave: Instrumentation | Agreement | Consistency | Smartphone | Measure | Observation
Área/s de conocimiento: Educación Física y Deportiva
Fecha de publicación: 30-jun-2018
Editor: University of Piteşti, Romania
Cita bibliográfica: Journal of Physical Education and Sport (JPES). 2018, 18(2), Art 121: 821-824. doi:10.7752/jpes.2018.02121
Resumen: Smartphone apps have been very popular among researchers, coaches and clinicians. The aim of this study was to analyze the inter-rater reliability of trained and untrained raters of the iOs app MyJump. Eighteen participants completed eight counter-movement jumps (CMJ) each (n=144) which were recorded using the app. In order to examine inter-rater reliability derived from raters’ experience, independent assessments were obtained by an untrained rater and two trained raters of the same recordings. Results showed very high agreement between trained raters (ICC=0.982, α=0.991) and between trained and untrained raters (ICC=0.984, α=0.992). Bland-Altman plots depicted negligible bias between both types of raters. Finally, very good internal consistency was found, regardless of experience (α from 0.995 to 0.997 and CV from 1.1 to 1.4%). This study have shown no significant difference in performance of trained and untrained raters of MyJump, and therefore no special training must be observed for an accurate use of the app.
URI: http://hdl.handle.net/10045/77068
ISSN: 2247-8051 (Print) | 2247-806X (Online)
DOI: 10.7752/jpes.2018.02121
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0
Revisión científica: si
Versión del editor: https://doi.org/10.7752/jpes.2018.02121
Aparece en las colecciones:INV - SCAPE - Artículos de Revistas
INV - HEALTH-TECH - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Pueo_etal_JPES.pdf236,69 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.