Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/75091
Información del item - Informació de l'item - Item information
Título: Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery
Autor/es: Camps, Vicente J. | Miret, Juan Jose | García Llopis, Celia | Tolosa, Ángel | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV) | Óptica y Ciencias de la Visión
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Optical performance | Presbyopia-correcting intraocular lenses (IOLs) | Laser refractive surgery
Área/s de conocimiento: Óptica
Fecha de publicación: abr-2018
Editor: SLACK Incorporated
Cita bibliográfica: Journal of Refractive Surgery. 2018, 34(4): 222-227. doi:10.3928/1081597X-20180130-02
Resumen: PURPOSE: To simulate the optical performance of three presbyopia-correcting intraocular lenses (IOLs) implanted in eyes with previous laser refractive surgery. METHODS: A simulation of the through-focus modulation transfer function (MTF) was performed for three presbyopia-correcting IOLs (Mplus, Oculentis GmbH, Berlin, Germany; Symfony, Johnson & Johnson Vision, Santa Ana, CA; and Mini Well, SIFI S.p.A., Lavinaio, Italy) in one eye with previous myopic LASIK and another with hyperopic LASIK. Real topographic data and the wavefront aberration profile of each IOL obtained with a Hartmann–Shack sensor were used. RESULTS: In the eye with myopic LASIK, all IOLs lost optical quality at near and intermediate distances for 4- and 4.7-mm pupil size. For 3-mm pupil size, the Mini Well IOL showed the best intermediate and near MTF and maintained the far focus independently of the pupil. In the eye with hyperopic LASIK, the Mini Well IOL showed an intermediate, distance, and −4.00-diopter (D) foci for all pupils. The Symfony IOL showed a depth of focus at far and intermediate distance for 3-mm and a focus at −2.50 D in the rest. The Mplus showed a focus of −4.50 and −3.00 D for the 3- and 4-mm pupil, respectively. CONCLUSIONS: The Mini Well and Symfony IOLs seem to work better than the Mplus IOL in eyes with previous myopic LASIK. With previous hyperopic LASIK, the Mini Well IOL seems to be able to provide acceptable near, intermediate, and far foci for all pupil sizes. These findings should be confirmed in future clinical studies.
URI: http://hdl.handle.net/10045/75091
ISSN: 1081-597X (Print) | 1938-2391 (Online)
DOI: 10.3928/1081597X-20180130-02
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © SLACK Incorporated
Revisión científica: si
Versión del editor: https://doi.org/10.3928/1081597X-20180130-02
Aparece en las colecciones:INV - IMAOS+V - Artículos de Revistas
INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Camps_etal_JRefractSurg_final.pdfVersión final (acceso restringido)2 MBAdobe PDFAbrir    Solicitar una copia
Thumbnail2018_Camps_etal_JRefractSurg_preprint.pdfPreprint (acceso abierto)1,41 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.