Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery
Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/10045/75091
Título: | Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery |
---|---|
Autor/es: | Camps, Vicente J. | Miret, Juan Jose | García Llopis, Celia | Tolosa, Ángel | Piñero, David P. |
Grupo/s de investigación o GITE: | Grupo de Óptica y Percepción Visual (GOPV) | Óptica y Ciencias de la Visión |
Centro, Departamento o Servicio: | Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía |
Palabras clave: | Optical performance | Presbyopia-correcting intraocular lenses (IOLs) | Laser refractive surgery |
Área/s de conocimiento: | Óptica |
Fecha de publicación: | abr-2018 |
Editor: | SLACK Incorporated |
Cita bibliográfica: | Journal of Refractive Surgery. 2018, 34(4): 222-227. doi:10.3928/1081597X-20180130-02 |
Resumen: | PURPOSE: To simulate the optical performance of three presbyopia-correcting intraocular lenses (IOLs) implanted in eyes with previous laser refractive surgery. METHODS: A simulation of the through-focus modulation transfer function (MTF) was performed for three presbyopia-correcting IOLs (Mplus, Oculentis GmbH, Berlin, Germany; Symfony, Johnson & Johnson Vision, Santa Ana, CA; and Mini Well, SIFI S.p.A., Lavinaio, Italy) in one eye with previous myopic LASIK and another with hyperopic LASIK. Real topographic data and the wavefront aberration profile of each IOL obtained with a Hartmann–Shack sensor were used. RESULTS: In the eye with myopic LASIK, all IOLs lost optical quality at near and intermediate distances for 4- and 4.7-mm pupil size. For 3-mm pupil size, the Mini Well IOL showed the best intermediate and near MTF and maintained the far focus independently of the pupil. In the eye with hyperopic LASIK, the Mini Well IOL showed an intermediate, distance, and −4.00-diopter (D) foci for all pupils. The Symfony IOL showed a depth of focus at far and intermediate distance for 3-mm and a focus at −2.50 D in the rest. The Mplus showed a focus of −4.50 and −3.00 D for the 3- and 4-mm pupil, respectively. CONCLUSIONS: The Mini Well and Symfony IOLs seem to work better than the Mplus IOL in eyes with previous myopic LASIK. With previous hyperopic LASIK, the Mini Well IOL seems to be able to provide acceptable near, intermediate, and far foci for all pupil sizes. These findings should be confirmed in future clinical studies. |
URI: | http://hdl.handle.net/10045/75091 |
ISSN: | 1081-597X (Print) | 1938-2391 (Online) |
DOI: | 10.3928/1081597X-20180130-02 |
Idioma: | eng |
Tipo: | info:eu-repo/semantics/article |
Derechos: | © SLACK Incorporated |
Revisión científica: | si |
Versión del editor: | https://doi.org/10.3928/1081597X-20180130-02 |
Aparece en las colecciones: | INV - IMAOS+V - Artículos de Revistas INV - GOPV - Artículos de Revistas |
Archivos en este ítem:
Archivo | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2018_Camps_etal_JRefractSurg_final.pdf | Versión final (acceso restringido) | 2 MB | Adobe PDF | Abrir Solicitar una copia |
2018_Camps_etal_JRefractSurg_preprint.pdf | Preprint (acceso abierto) | 1,41 MB | Adobe PDF | Abrir Vista previa |
Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.