Parametric computational analysis for punching shear in RC slabs

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/74779
Información del item - Informació de l'item - Item information
Títol: Parametric computational analysis for punching shear in RC slabs
Autors: Navarro Menargues, Miguel | Ivorra, Salvador | Varona Moya, Francisco de Borja
Grups d'investigació o GITE: Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES)
Centre, Departament o Servei: Universidad de Alicante. Departamento de Ingeniería Civil
Paraules clau: Punching shear | Reinforced concrete | Flat slabs | Nonlinearity | Parametric analysis | FEM analysis | Concrete damaged plasticity
Àrees de coneixement: Mecánica de Medios Continuos y Teoría de Estructuras
Data de publicació: 15-de juny-2018
Editor: Elsevier
Citació bibliogràfica: Engineering Structures. 2018, 165: 254-263. doi:10.1016/j.engstruct.2018.03.035
Resum: One of the key phenomena in flat slab structures is their punching shear behaviour. The real importance of punching shear consists of a sudden brittle fracture, which can trigger catastrophic consequences for humans. This paper presents a nonlinear numerical model based on finite elements in order to study the punching shear phenomenon of reinforced slabs. The numerical model developed has been configured with hexahedral 3D elements for concrete and linear elements (2D truss) for steel reinforcements. Constitutive equations for concrete and steel include the nonlinearity of these materials. The slab has been simulated in ABAQUS software and the model has been calibrated in comparison to experimental results developed in the University of Waterloo by Adetifa and Polak, and some additional analytical results developed by Polak, in order to validate the model. The calibration has also been contrasted with some experimental results from ACI database for punching tests. Afterwards, a parametric analysis has been performed to study the influence of different geometric and mechanical parameters which define a classic slab-column structure. This discussion also addresses the adequacy of some mechanical approaches, such as the CEB Model Code 2010.
URI: http://hdl.handle.net/10045/74779
ISSN: 0141-0296 (Print) | 1873-7323 (Online)
DOI: 10.1016/j.engstruct.2018.03.035
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © 2018 Elsevier Ltd.
Revisió científica: si
Versió de l'editor: https://doi.org/10.1016/j.engstruct.2018.03.035
Apareix a la col·lecció: INV - GRESMES - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2018_Navarro_etal_EngStruct_final.pdfVersión final (acceso restringido)2,08 MBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.