Seismic behavior of 1960's RC buildings exposed to marine environment

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/74773
Información del item - Informació de l'item - Item information
Título: Seismic behavior of 1960's RC buildings exposed to marine environment
Autor/es: Bru, David | González Sánchez, Antonio | Baeza, F. Javier | Ivorra, Salvador
Grupo/s de investigación o GITE: Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES) | Durabilidad de Materiales y Construcciones en Ingeniería y Arquitectura
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Ingeniería Civil
Palabras clave: Seismic loads | Plastic hinge | Vulnerability | RC building corrosion | Marine environment
Área/s de conocimiento: Mecánica de Medios Continuos y Teoría de Estructuras
Fecha de publicación: ago-2018
Editor: Elsevier
Cita bibliográfica: Engineering Failure Analysis. 2018, 90: 324-340. doi:10.1016/j.engfailanal.2018.02.011
Resumen: Steel rebars corrosion is one of the most important problems of reinforced concrete (RC) structures. The mechanical performance loss of RC elements because of steel corrosion can be aggravated under horizontal loads (e.g. wind pressure or seismic actions). This paper presents a methodology for the study of the seismic behavior of a residential typology of the Mediterranean coast, which was widely spread during the 1960's. These RC frame structures are usually 10 to 15 stories high, located very close to the coast and are exempt buildings, which made them specially exposed to chloride corrosion. Besides, there are some design conditions that should be taken into account: (i) these structures were designed only under gravity loads, especially seismic actions were not considered. (ii) The raw materials had lower quality than those considered in current design codes, e.g. structural concrete strength was around 15 MPa, and made with natural beach sand as fine aggregates (hence including chlorides into the concrete mass). Therefore, two important aspects converge in these buildings, fifty years of marine exposure (i.e. degradation by corrosion) and the omission of the seismic loads in the original design, making them especially vulnerable to earthquakes (in an area with a moderate-high seismicity). Hence, a methodology for the seismic analysis of the corroded structure is proposed, in order to determine the structural safety factor of this type of structures, and evaluate the effectiveness of a retrofitting if necessary.
URI: http://hdl.handle.net/10045/74773
ISSN: 1350-6307 (Print) | 1873-1961 (Online)
DOI: 10.1016/j.engfailanal.2018.02.011
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2018 Elsevier Ltd.
Revisión científica: si
Versión del editor: https://doi.org/10.1016/j.engfailanal.2018.02.011
Aparece en las colecciones:INV - GRESMES - Artículos de Revistas
INV - DMCIA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Bru_etal_EngFailAnal_final.pdfVersión final (acceso restringido)1,92 MBAdobe PDFAbrir    Solicitar una copia
Thumbnail2018_Bru_etal_EngFailAnal_accepted.pdfAccepted Manuscript (acceso abierto)2,35 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.