Corneal Stability following Hyperopic LASIK with Advanced Laser Ablation Profiles Analyzed by a Light Propagation Study

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/74675
Información del item - Informació de l'item - Item information
Título: Corneal Stability following Hyperopic LASIK with Advanced Laser Ablation Profiles Analyzed by a Light Propagation Study
Autor/es: Gharaibeh, Almutez M. | Villanueva, Asier | Mas, David | Espinosa, Julián | Alió, Jorge L.
Grupo/s de investigación o GITE: Óptica y Ciencias de la Visión
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Corneal stability | Hyperopic LASIK | Advanced laser ablation profiles | Light propagation study
Área/s de conocimiento: Óptica
Fecha de publicación: 28-mar-2018
Editor: Hindawi Publishing Corporation
Cita bibliográfica: Journal of Ophthalmology. Volume 2018 (2018), Article ID 3060939, 10 pages. doi:10.1155/2018/3060939
Resumen: Purpose. To assess anterior corneal surface stability 12 months following hyperopic LASIK correction with a light propagation algorithm. Setting. Vissum Instituto Oftalmológico de Alicante, Universidad Miguel Hernández, Alicante, Spain. Methods. This retrospective consecutive observational study includes 37 eyes of 37 patients treated with 6th-generation excimer laser platform (Schwind Amaris). Hyperopic LASIK was performed in all of them by the same surgeon (JLA) and completed 12-month follow-up. Corneal topography was analyzed with a light propagation algorithm, to assess the stability of the corneal outcomes along one year of follow-up. Results. Between three and twelve months postoperatively, an objective corneal power (OCP) regression of 0.39 D and 0.41 D was found for 6 mm and 9 mm central corneal zone, respectively. Subjective outcomes at the end of the follow-up period were as follows: 65% of eyes had spherical equivalent within ±0.50 D. 70% of eyes had an uncorrected distance visual acuity 20/20 or better. 86% of eyes had the same or better corrected distance visual acuity. In terms of stability, 0.14 D of regression was found. No statistically significant differences were found for all the study parameters evaluated at different postoperative moments over the 12-month period. Conclusions. Light propagation analysis confirms corneal surface stability following modern hyperopic LASIK with a 6th-generation excimer laser technology over a 12-month period.
Patrocinador/es: This publication has been carried out in the framework of the Red Temática de Investigación Cooperativa en Salud (RETICS), reference number RD12/0034/0007 and RD16/0008/0012, financed by the Instituto Carlos III-General Subdirection of Networks and Cooperative Investigation Centers (R&D&I National Plan 2008-2011) and the European Regional Development Fund (Fondo europeo de desarrollo regional FEDER.This publication has been carried out in the framework of the Red Temática de Investigación Cooperativa en Salud (RETICS), reference number RD12/0034/0007.
URI: http://hdl.handle.net/10045/74675
ISSN: 2090-004X (Print) | 2090-0058 (Online)
DOI: 10.1155/2018/3060939
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2018 Almutez M. Gharaibeh et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Revisión científica: si
Versión del editor: https://doi.org/10.1155/2018/3060939
Aparece en las colecciones:INV - IMAOS+V - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2018_Gharaibeh_etal_JOphthalmology.pdf1,92 MBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons