Autofocus method for automated microscopy using embedded GPUs
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/66767
Títol: | Autofocus method for automated microscopy using embedded GPUs |
---|---|
Autors: | Castillo-Secilla, José María | Saval-Calvo, Marcelo | Medina-Valdés, Luis | Cuenca-Asensi, Sergio | Martínez-Álvarez, Antonio | Sánchez, Carlos | Cristóbal, Gabriel |
Grups d'investigació o GITE: | Informática Industrial y Redes de Computadores | UniCAD: Grupo de Investigación en CAD/CAM/CAE de la Universidad de Alicante |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Tecnología Informática y Computación | Universidad de Alicante. Instituto Universitario de Investigación Informática |
Paraules clau: | Image processing | Microscopy | Vision, color, and visual optics |
Àrees de coneixement: | Arquitectura y Tecnología de Computadores |
Data de publicació: | 1-de març-2017 |
Editor: | Optical Society of America |
Citació bibliogràfica: | Biomedical Optics Express. 2017, 8(3): 1731-1740. doi:10.1364/BOE.8.001731 |
Resum: | In this paper we present a method for autofocusing images of sputum smears taken from a microscope which combines the finding of the optimal focus distance with an algorithm for extending the depth of field (EDoF). Our multifocus fusion method produces an unique image where all the relevant objects of the analyzed scene are well focused, independently to their distance to the sensor. This process is computationally expensive which makes unfeasible its automation using traditional embedded processors. For this purpose a low-cost optimized implementation is proposed using limited resources embedded GPU integrated on cutting-edge NVIDIA system on chip. The extensive tests performed on different sputum smear image sets show the real-time capabilities of our implementation maintaining the quality of the output image. |
Patrocinadors: | This work has been partly supported by the Spanish grant CTM2014-51907. |
URI: | http://hdl.handle.net/10045/66767 |
ISSN: | 2156-7085 |
DOI: | 10.1364/BOE.8.001731 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © 2017 Optical Society of America |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1364/BOE.8.001731 |
Apareix a la col·lecció: | INV - I2RC - Artículos de Revistas INV - UNICAD - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
2017_Castillo_etal_BiomedOptExpr_final.pdf | Versión final (acceso restringido) | 2,94 MB | Adobe PDF | Obrir Sol·licitar una còpia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.