Energy potential and alternative usages of biogas and sludge from UASB reactors: case study of the Laboreaux wastewater treatment plant

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/65693
Información del item - Informació de l'item - Item information
Título: Energy potential and alternative usages of biogas and sludge from UASB reactors: case study of the Laboreaux wastewater treatment plant
Autor/es: Rosa, André Pereira | Conesa, Juan A. | Fullana, Andres | Lobato, Lívia Cristina da Silva | Borges, Jorge Martins | Melo, Gilberto Caldeira Bandeira de | Chernicharo, Carlos Augusto de Lemos
Grupo/s de investigación o GITE: Residuos, Energía, Medio Ambiente y Nanotecnología (REMAN)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Ingeniería Química | Universidad de Alicante. Instituto Universitario de Ingeniería de los Procesos Químicos
Palabras clave: Biogas | Energy recovery | Sludge | Wastewater treatment | UASB reactors
Área/s de conocimiento: Ingeniería Química
Fecha de publicación: abr-2016
Editor: IWA Publishing
Cita bibliográfica: Water Science and Technology. 2016, 73(7): 1680-1690. doi:10.2166/wst.2015.643
Resumen: This work assessed the energy potential and alternative usages of biogas and sludge generated in upflow anaerobic sludge blanket reactors at the Laboreaux sewage treatment plant (STP), Brazil. Two scenarios were considered: (i) priority use of biogas for the thermal drying of dehydrated sludge and the use of the excess biogas for electricity generation in an ICE (internal combustion engine); and (ii) priority use of biogas for electricity generation and the use of the heat of the engine exhaust gases for the thermal drying of the sludge. Scenario 1 showed that the electricity generated is able to supply 22.2% of the STP power demand, but the thermal drying process enables a greater reduction or even elimination of the final volume of sludge to be disposed. In Scenario 2, the electricity generated is able to supply 57.6% of the STP power demand; however, the heat in the exhaust gases is not enough to dry the total amount of dehydrated sludge.
URI: http://hdl.handle.net/10045/65693
ISSN: 0273-1223 (Print) | 1996-9732 (Online)
DOI: 10.2166/wst.2015.643
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © IWA Publishing 2016
Revisión científica: si
Versión del editor: http://dx.doi.org/10.2166/wst.2015.643
Aparece en las colecciones:INV - REMAN - Artículos de Revistas
INV - I4CE - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2016_Rosa_etal_WaterSciTech_rev.pdfVersión revisada (acceso abierto)1,35 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.