Tungsten coil atomic emission spectrometry combined with dispersive liquid–liquid microextraction: A synergistic association for chromium determination in water samples

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/51806
Información del item - Informació de l'item - Item information
Título: Tungsten coil atomic emission spectrometry combined with dispersive liquid–liquid microextraction: A synergistic association for chromium determination in water samples
Autor/es: Vidal, Lorena | Silva, Sidnei G. | Canals, Antonio | Nóbrega, Joaquim A.
Grupo/s de investigación o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Palabras clave: Atomic emission | Chromium | Dispersive liquid–liquid microextraction | Ionic liquids | Speciation | Tungsten coil atomizer | Water samples
Área/s de conocimiento: Nutrición y Bromatología | Química Analítica
Fecha de publicación: 1-feb-2016
Editor: Elsevier
Cita bibliográfica: Talanta. 2016, 148: 602-608. doi:10.1016/j.talanta.2015.04.023
Resumen: A novel and environment friendly analytical method is reported for total chromium determination and chromium speciation in water samples, whereby tungsten coil atomic emission spectrometry (WCAES) is combined with in situ ionic liquid formation dispersive liquid–liquid microextraction (in situ IL-DLLME). A two stage multivariate optimization approach has been developed employing a Plackett–Burman design for screening and selection of the significant factor involved in the in situ IL-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were complexant concentration: 0.5% (or 0.1%); complexant type: DDTC; IL anion: View the MathML sourcePF6−; [Hmim][Cl] IL amount: 60 mg; ionic strength: 0% NaCl; pH: 5 (or 2); centrifugation time: 10 min; and centrifugation speed: 1000 rpm. Under the optimized experimental conditions the method was evaluated and proper linearity was obtained with a correlation coefficient of 0.991 (5 calibration standards). Limits of detection and quantification for both chromium species were 3 and 10 µg L−1, respectively. This is a 233-fold improvement when compared with chromium determination by WCAES without using preconcentration. The repeatability of the proposed method was evaluated at two different spiking levels (10 and 50 µg L−1) obtaining coefficients of variation of 11.4% and 3.6% (n=3), respectively. A certified reference material (SRM-1643e NIST) was analyzed in order to determine the accuracy of the method for total chromium determination and 112.3% and 2.5 µg L−1 were the recovery (trueness) and standard deviation values, respectively. Tap, bottled mineral and natural mineral water samples were analyzed at 60 µg L−1 spiking level of total Cr content at two Cr(VI)/Cr(III) ratios, and relative recovery values ranged between 88% and 112% showing that the matrix has a negligible effect. To our knowledge, this is the first time that combines in situ IL-DLLME and WCAES.
Patrocinador/es: The authors would like to thank the Spanish Ministry of Science and Innovation (Project no. CTQ2011-23968), Spanish Ministry of Education, Culture and Sport (Project no. PHB2010-0018-PC), Generalitat Valenciana (Spain) (Project no. ACOMP/2013/072), and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior in Brazil (Grant CAPES-DGU n. 243/11). L. Vidal also thanks the Spanish Ministry of Education, Culture and Sport for her travel Grant (HBP-2010-0030) and S.G. Silva is grateful to the Grant 2011/13288-7, São Paulo Research Foundation (FAPESP).
URI: http://hdl.handle.net/10045/51806
ISSN: 0039-9140 (Print) | 1873-3573 (Online)
DOI: 10.1016/j.talanta.2015.04.023
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2015 Elsevier B.V.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.talanta.2015.04.023
Aparece en las colecciones:INV - SP-BG - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2016_Vidal_etal_Talanta_final.pdfVersión final (acceso restringido)565,74 kBAdobe PDFAbrir    Solicitar una copia
Thumbnail2016_Vidal_etal_Talanta_accepted.pdfAccepted Manuscript (acceso abierto)792,2 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.