Errors Associated to Keratoconus Grading using Systems based on Corneal Power

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/49698
Información del item - Informació de l'item - Item information
Título: Errors Associated to Keratoconus Grading using Systems based on Corneal Power
Autor/es: Piñero, David P. | Camps, Vicente J. | Caravaca Arens, Esteban
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Corneal topography | Keratoconus | Pentacam
Área/s de conocimiento: Óptica
Fecha de publicación: 2015
Editor: Jaypee Brothers Medical Publishers
Cita bibliográfica: Piñero-Llorens DP, Camps V, Caravaca-Arens E. Errors Associated to Keratoconus Grading using Systems based on Corneal Power. Int J Kerat Ect Cor Dis 2015;4(2):41-46. doi:10.5005/jp-journals-10025-1096
Resumen: Purpose: To analyze and define the possible errors that may be introduced in keratoconus classification when the keratometric corneal power is used in such classification. Materials and methods: Retrospective study including a total of 44 keratoconus eyes. A comprehensive ophthalmologic examination was performed in all cases, which included a corneal analysis with the Pentacam system (Oculus). Classical keratometric corneal power (Pk), Gaussian corneal power (Pc Gauss), True Net Power (TNP) (Gaussian power neglecting the corneal thickness effect), and an adjusted keratometric corneal power (Pkadj) (keratometric power considering a variable keratometric index) were calculated. All cases included in the study were classified according to five different classification systems: Alió-Shabayek, Amsler-Krumeich, Rabinowitz-McDonnell, collaborative longitudinal evaluation of keratoconus (CLEK), and McMahon. Results: When Pk and Pkadj were compared, differences in the type of grading of keratoconus cases was found in 13.6% of eyes when the Alió-Shabayek or the Amsler-Krumeich systems were used. Likewise, grading differences were observed in 22.7% of eyes with the Rabinowitz-McDonnell and McMahon classification systems and in 31.8% of eyes with the CLEK classification system. All reclassified cases using Pkadj were done in a less severe stage, indicating that the use of Pk may lead to the classification of a cornea as keratoconus, being normal. In general, the results obtained using Pkadj, Pc Gauss or the TNP were equivalent. Differences between Pkadj and Pc Gauss were within ± 0.7D. Conclusion: The use of classical keratometric corneal power may lead to incorrect grading of the severity of keratoconus, with a trend to a more severe grading.
URI: http://hdl.handle.net/10045/49698
ISSN: 2277-3800 (Print) | 2277-4203 (Online)
DOI: 10.5005/jp-journals-10025-1096
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © Jaypee Brothers Medical Publishers (P) Ltd.
Revisión científica: si
Versión del editor: http://www.ijkecd.com/
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2015_Pinero_etal_IJKECD.pdf635,14 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.