New-Generation Hybrid Contact Lens for the Management of Extreme Irregularity in a Thin Cornea After Unsuccessful Excimer Laser Refractive Surgery

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/46559
Información del item - Informació de l'item - Item information
Título: New-Generation Hybrid Contact Lens for the Management of Extreme Irregularity in a Thin Cornea After Unsuccessful Excimer Laser Refractive Surgery
Autor/es: Piñero, David P. | Pérez Cambrodí, Rafael J. | Ruiz Fortes, Pedro | Blanes Mompó, Francisco J.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Hybrid contact lens | SynergEyes | Central Island | Corneal irregularity | Refractive surgery
Área/s de conocimiento: Óptica
Fecha de publicación: may-2014
Editor: Lippincott, Williams & Wilkins
Cita bibliográfica: Eye & Contact Lens. 2014, 40(3): e16-e20. doi:10.1097/ICL.0b013e31829e8f90
Resumen: Purpose: To report a very successful outcome obtained with the fitting of a new-generation hybrid contact lens of reverse geometry in a thin cornea with extreme irregularity due to the presence of a central island after unsuccessful myopic excimer laser refractive surgery. Methods: A 32-year-old man attended to our clinic complaining of very poor vision in his right eye after bilateral laser in situ keratomileusis (treatment or surgery) for myopia correction and some additional retreatments afterward. After a comprehensive ocular evaluation, contact lens fitting with a reverse geometry hybrid contact lens (SynergEyes PS, SynergEyes, Carlsbad, CA) was proposed as a solution for this case. Visual, refractive, and ocular aberrometric outcomes with the contact lens were evaluated. Results: Distance visual acuity improved from a prefitting uncorrected value of 20/200 to a postfitting corrected value of 20/16. Prefitting manifest refraction was +6.00 sphere and −3.00 cylinder at 70°, with a corrected distance visual acuity of 20/40. Higher order root mean square for a 5-mm pupil changed from a prefitting value of 1.45 to 0.34 µm with the contact lens. The contact lens wearing was reported as comfortable, and the patient was very satisfied with this solution. Conclusions: The SynergEyes PS contact lens seems to be an excellent option for the visual rehabilitation of corneas with extreme irregularity after myopic excimer laser surgery, minimizing the level of higher order aberrations and providing an excellent visual outcome.
URI: http://hdl.handle.net/10045/46559
ISSN: 1542-2321 (Print) | 1542-233X (Online)
DOI: 10.1097/ICL.0b013e31829e8f90
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2014 Contact Lens Association of Ophthalmologists, Inc.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1097/ICL.0b013e31829e8f90
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2014_Pinero_etal_Eye&ContactLens_final.pdfVersión final (acceso restringido)632,19 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.