Reliability in perimetric multichannel contrast sensitivity measurements

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/46347
Información del item - Informació de l'item - Item information
Title: Reliability in perimetric multichannel contrast sensitivity measurements
Authors: Fez Saiz, Dolores de | Capilla Perea, Pascual | Camps, Vicente J. | Luque Cobija, María José | Moncho Gascón, Vicenta
Research Group/s: Grupo de Óptica y Percepción Visual (GOPV)
Center, Department or Service: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Keywords: Multichannel perimetry | Repeatability | Reproducibility | Agreement | Contrast sensitivity
Knowledge Area: Óptica
Issue Date: Nov-2014
Publisher: Wiley
Citation: Clinical and Experimental Optometry. 2014, 97(6): 555-564. doi:10.1111/cxo.12193
Abstract: Background: In this study, the reliability of perimetric contrast sensitivity measurements favouring the achromatic, the red-green and the blue-yellow post-receptorial mechanisms was analysed. Methods: A new technique, multichannel ATD perimetry, provides spatial and temporal stimuli favouring the detection by an achromatic mechanism (A), from a magno or parvocellular origin or by a red-green (RG) chromatic mechanism, with a parvocellular origin or a blue-yellow (BY) mechanism, with a koniocellular origin. The repeatability and reproducibility of contrast sensitivity measurements with these stimuli were studied in a group of 40 healthy subjects. The analysis was carried out on 21 testing points within a 60° by 40° fovea-centred region of the visual field. Results: The within-observer repeatability for the four mechanisms studied is either good or excellent when the intra-class correlation coefficient (ICC) can be calculated. For the remaining points, the Friedman's test finds that the measurements are repeatable. The between-observer reproducibility was either excellent or good in cases where the ICC was applied and according to the Friedman's test all results were reproducible. Conclusions: The results obtained showed good repeatability and reproducibility with A, RG and BY stimuli, although with BY stimuli repeatability is slightly worse. Future studies on the diagnostic validity of this device are based on the fact that changes of sensitivity can be compared by means of a visual single task, contrast sensitivity measurement and using a common metric.
Sponsor: The ATD multichannel perimeter was built thanks to the support of the Spanish Ministerio de Ciencia y Tecnología Grants DPI2000-0116-P4-02 and PTR 1995-0909-OP, in collaboration with INDUSTRIAS DE OPTICA SA (San Cugat del Vallés, Spain).
URI: http://hdl.handle.net/10045/46347
ISSN: 0816-4622 (Print) | 1444-0938 (Online)
DOI: 10.1111/cxo.12193
Language: eng
Type: info:eu-repo/semantics/article
Rights: © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia
Peer Review: si
Publisher version: http://dx.doi.org/10.1111/cxo.12193
Appears in Collections:INV - GOPV - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2014_de-Fez_etal_CEO_final.pdfVersión final (acceso restringido)351,77 kBAdobe PDFOpen    Request a copy
Thumbnail2014_de-Fez_etal_CEO_rev.pdfPreprint (acceso abierto)1,18 MBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.