A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/45821
Información del item - Informació de l'item - Item information
Título: A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement
Autor/es: Espinosa, Julián | Roig Hernández, Ana Belén | Pérez Rodríguez, Jorge | Mas, David
Grupo/s de investigación o GITE: Óptica y Ciencias de la Visión
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologías
Palabras clave: Binocular measurement | Pupillary light reflex | Early incomplete blink | Bell’s phenomenon
Área/s de conocimiento: Óptica
Fecha de publicación: 13-mar-2015
Editor: BioMed Central
Cita bibliográfica: BioMedical Engineering OnLine. 2015, 14:22. doi:10.1186/s12938-015-0016-6
Resumen: Background: The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked to activation of the same midbrain area. The latency of the pupillary light reflex is around 200 ms, although the literature also indicates that the fastest eye reflexes last 20 ms. Therefore, a system with sufficiently high spatial and temporal resolutions is required for accurate assessment. In this study, we analyzed the pupillary light reflex to determine whether any small discrepancy exists between the direct and consensual responses, and to ascertain whether any other eye reflex occurs before the pupillary light reflex. Methods: We constructed a binocular video-oculography system two high-speed cameras that simultaneously focused on both eyes. This was then employed to assess the direct and consensual responses of each eye using our own algorithm based on Circular Hough Transform to detect and track the pupil. Time parameters describing the pupillary light reflex were obtained from the radius time-variation. Eight healthy subjects (4 women, 4 men, aged 24–45) participated in this experiment. Results: Our system, which has a resolution of 15 microns and 4 ms, obtained time parameters describing the pupillary light reflex that were similar to those reported in previous studies, with no significant differences between direct and consensual reflexes. Moreover, it revealed an incomplete reflex blink and an upward eye movement at around 100 ms that may correspond to Bell’s phenomenon. Conclusions: Direct and consensual pupillary responses do not any significant temporal differences. The system and method described here could prove useful for further assessment of pupillary and blink reflexes. The resolution obtained revealed the existence reported here of an early incomplete blink and an upward eye movement.
Patrocinador/es: The authors acknowledge the support of the Spanish Ministerio de Economía y Competitividad through the project BIA2011-22704 and the Generalitat Valenciana through the projects GV/2013/009 and PROMETEO/2011/021. A. B. Roig acknowledges a grant from Cajamurcia.
URI: http://hdl.handle.net/10045/45821
ISSN: 1475-925X
DOI: 10.1186/s12938-015-0016-6
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2015 Espinosa et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1186/s12938-015-0016-6
Aparece en las colecciones:INV - IMAOS+V - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnailespinosa_et_al_15.pdf3,2 MBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons