Screen-printed electrode based electrochemical detector coupled with ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction for determination of mercury in water samples

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/44108
Información del item - Informació de l'item - Item information
Títol: Screen-printed electrode based electrochemical detector coupled with ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction for determination of mercury in water samples
Autors: Fernández Martínez, Elena | Vidal, Lorena | Martín-Yerga, Daniel | Blanco, María del Carmen | Canals, Antonio | Costa-García, Agustín
Grups d'investigació o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Paraules clau: Liquid-phase microextraction | Dispersive liquid–liquid microextraction | Ionic liquid | Mercury | Screen-printed electrode | Water samples
Àrees de coneixement: Química Analítica
Data de publicació: 1-d’abril-2015
Editor: Elsevier
Citació bibliogràfica: Talanta. 2015, 135: 34-40. doi:10.1016/j.talanta.2014.11.069
Resum: A novel approach is presented, whereby gold nanostructured screen-printed carbon electrodes (SPCnAuEs) are combined with in-situ ionic liquid formation dispersive liquid–liquid microextraction (in-situ IL-DLLME) and microvolume back-extraction for the determination of mercury in water samples. In-situ IL-DLLME is based on a simple metathesis reaction between a water-miscible IL and a salt to form a water-immiscible IL into sample solution. Mercury complex with ammonium pyrrolidinedithiocarbamate is extracted from sample solution into the water-immiscible IL formed in-situ. Then, an ultrasound-assisted procedure is employed to back-extract the mercury into 10 µL of a 4 M HCl aqueous solution, which is finally analyzed using SPCnAuEs. Sample preparation methodology was optimized using a multivariate optimization strategy. Under optimized conditions, a linear range between 0.5 and 10 µg L−1 was obtained with a correlation coefficient of 0.997 for six calibration points. The limit of detection obtained was 0.2 µg L−1, which is lower than the threshold value established by the Environmental Protection Agency and European Union (i.e., 2 µg L−1 and 1 µg L−1, respectively). The repeatability of the proposed method was evaluated at two different spiking levels (3 and 10 µg L−1) and a coefficient of variation of 13% was obtained in both cases. The performance of the proposed methodology was evaluated in real-world water samples including tap water, bottled water, river water and industrial wastewater. Relative recoveries between 95% and 108% were obtained.
Patrocinadors: The authors would like to thank the Spanish Ministry of Science and Innovation (Project nos. CTQ2011-23968 and CTQ2011-24560), the Generalitat Valenciana (Spain) (Project nos. ACOMP/2013/072, PROMETEO/2013/038 and GV/2014/096) and the University of Alicante (Spain) (Project no. GRE12-45) for the financial support. E. Fernández and D. Martín-Yerga also thank Generalitat Valenciana and Ministry of Economy and Competitiveness, respectively, for their fellowships.
URI: http://hdl.handle.net/10045/44108
ISSN: 0039-9140 (Print) | 1873-3573 (Online)
DOI: 10.1016/j.talanta.2014.11.069
Idioma: eng
Tipus: info:eu-repo/semantics/article
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.talanta.2014.11.069
Apareix a la col·lecció: INV - SP-BG - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2015_Fernandez_etal_Talanta_final.pdfVersión final (acceso restringido)756,87 kBAdobe PDFObrir     Sol·licitar una còpia
Thumbnail2015_Fernandez_etal_Talanta.pdfAccepted Manuscript (acceso abierto)756,05 kBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.