Evaluation of Binocular Vision Therapy Efficacy by 3D Video-Oculography Measurement of Binocular Alignment and Motility

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/43000
Información del item - Informació de l'item - Item information
Título: Evaluation of Binocular Vision Therapy Efficacy by 3D Video-Oculography Measurement of Binocular Alignment and Motility
Autor/es: Laria Ochaíta, Carlos | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Binocular vision | Therapy efficacy | 3D video-oculography | Binocular alignment | Motility
Área/s de conocimiento: Óptica
Fecha de publicación: 2013
Editor: Binoculus Publishing
Cita bibliográfica: Binocular Vision & Strabology Quarterly, Simms-Romano’s. 2013, 28(3): 136-145
Resumen: Objective: To evaluate two cases of intermittent exotropia (IX(T)) treated by vision therapy the efficacy of the treatment by complementing the clinical examination with a 3-D video-oculography to register and to evidence the potential applicability of this technology for such purpose. Methods: We report the binocular alignment changes occurring after vision therapy in a woman of 36 years with an IX(T) of 25 prism diopters (Δ) at far and 18 Δ at near and a child of 10 years with 8 Δ of IX(T) in primary position associated to 6 Δ of left eye hypotropia. Both patients presented good visual acuity with correction in both eyes. Instability of ocular deviation was evident by VOG analysis, revealing also the presence of vertical and torsional components. Binocular vision therapy was prescribed and performed including different types of vergence, accommodation, and consciousness of diplopia training. Results: After therapy, excellent ranges of fusional vergence and a “to-the-nose” near point of convergence were obtained. The 3-D VOG examination (Sensoro Motoric Instruments, Teltow, Germany) confirmed the compensation of the deviation with a high level of stability of binocular alignment. Significant improvement could be observed after therapy in the vertical and torsional components that were found to become more stable. Patients were very satisfied with the outcome obtained by vision therapy. Conclusion: 3D-VOG is a useful technique for providing an objective register of the compensation of the ocular deviation and the stability of the binocular alignment achieved after vision therapy in cases of IX(T), providing a detailed analysis of vertical and torsional improvements.
URI: http://hdl.handle.net/10045/43000
ISSN: 2160-5351 (Print) | 2160-5904 (Online)
Idioma: eng
Tipo: info:eu-repo/semantics/article
Revisión científica: si