Power line interference filtering on surface electromyography based on the stationary wavelet packet transform

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/39284
Información del item - Informació de l'item - Item information
Títol: Power line interference filtering on surface electromyography based on the stationary wavelet packet transform
Autors: Galiana-Merino, Juan José | Ruiz-Fernandez, Daniel | Martínez Esplá, Juan José
Grups d'investigació o GITE: Sismología-Riesgo Sísmico y Procesado de la Señal en Fenómenos Naturales | Ingeniería Bioinspirada e Informática para la Salud
Centre, Departament o Servei: Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal | Universidad de Alicante. Departamento de Tecnología Informática y Computación | Universidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologías
Paraules clau: Electromyogram signal (EMG) | Biological signals filtering | Stationary wavelet packet transform (SWPT) | Power line interference
Àrees de coneixement: Teoría de la Señal y Comunicaciones | Arquitectura y Tecnología de Computadores
Data de publicació: d’agost-2013
Editor: Elsevier
Citació bibliogràfica: Computer Methods and Programs in Biomedicine. 2013, 111(2): 338-346. doi:10.1016/j.cmpb.2013.04.022
Resum: Power line interference is one of the main problems in surface electromyogram signals (EMG) analysis. In this work, a new method based on the stationary wavelet packet transform is proposed to estimate and remove this kind of noise from EMG data records. The performance has been quantitatively evaluated with synthetic noisy signals, obtaining good results independently from the signal to noise ratio (SNR). For the analyzed cases, the obtained results show that the correlation coefficient is around 0.99, the energy respecting to the pure EMG signal is 98–104%, the SNR is between 16.64 and 20.40 dB and the mean absolute error (MAE) is in the range of −69.02 and −65.31 dB. It has been also applied on 18 real EMG signals, evaluating the percentage of energy respecting to the noisy signals. The proposed method adjusts the reduction level to the amplitude of each harmonic present in the analyzed noisy signals (synthetic and real), reducing the harmonics with no alteration of the desired signal.
URI: http://hdl.handle.net/10045/39284
ISSN: 0169-2607 (Print) | 1872-7565 (Online)
DOI: 10.1016/j.cmpb.2013.04.022
Idioma: eng
Tipus: info:eu-repo/semantics/article
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.cmpb.2013.04.022
Apareix a la col·lecció: INV - IBIS - Artículos de Revistas
INV - GIRS - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2013_Galiana_etal_CMPB_final.pdfVersión final (acceso restringido)1,24 MBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.