Visual and optical performance and quality of life after implantation of posterior chamber phakic intraocular lens

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/39221
Información del item - Informació de l'item - Item information
Título: Visual and optical performance and quality of life after implantation of posterior chamber phakic intraocular lens
Autor/es: Pérez Cambrodí, Rafael J. | Blanes Mompó, Francisco J. | García Lázaro, Santiago | Piñero, David P. | Cerviño, Alejandro | Brautaset, Rune
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Posterior chamber phakic intraocular lens | PRL | Visual performance | Optical quality | Quality of life
Área/s de conocimiento: Óptica
Fecha de publicación: ene-2013
Editor: Springer
Cita bibliográfica: Graefe's Archive for Clinical and Experimental Ophthalmology. 2013, 251(1): 331-340. doi:10.1007/s00417-012-2041-5
Resumen: Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
URI: http://hdl.handle.net/10045/39221
ISSN: 0721-832X (Print) | 1435-702X (Online)
DOI: 10.1007/s00417-012-2041-5
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: The final publication is available at Springer via http://dx.doi.org/10.1007/s00417-012-2041-5
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1007/s00417-012-2041-5
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2013_Perez-Cambrodi_etal_GACEO_final.pdfVersión final (acceso restringido)312,86 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.