Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/37262
Información del item - Informació de l'item - Item information
Títol: Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry
Autors: Ávila Orozco, Francisco D. | Kovachev, Nikolay | Aguirre Pastor, Miguel Ángel | Domini, Claudia E. | Fernández Band, Beatriz S. | Canals, Antonio
Grups d'investigació o GITE: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales
Paraules clau: Multinebulizer | ICP OES | Inorganic elemental analysis | Biodiesel
Àrees de coneixement: Química Analítica
Data de publicació: 27-de maig-2014
Editor: Elsevier
Citació bibliogràfica: Analytica Chimica Acta. 2014, 827: 15-21. doi:10.1016/j.aca.2014.04.016
Resum: A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring® multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R2) were greater than 0.99 for the studied analytes, in the range 0.21–14.75 mg kg−1. Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g−1 for Mg (279.553 nm) and 531.1 ng g−1 for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g−1 for Ba (455.403 nm) and 2913.9 ng g−1 for Pb (220.353 nm). Recovery values ranged between 95% and 106%.
Patrocinadors: The authors gratefully acknowledge Universidad Nacional del Sur (UNS) and Instituto de Química del Sur – Universidad Nacional del Sur – Consejo Nacional de Investigaciones Científicas y Técnicas (INQUISUR-UNS-CONICET) from Argentina for the financial support. FDAO acknowledges Universidad de Alicante (UA) for his short visit fellowship. Ministerio de Asuntos Exteriores y de Cooperación (MAEC) and Dirección de Relaciones Culturales y Científicas (AECID) from Spain for the financial support. The authors wish to thank the Spanish Government (CTQ2011-23968) for the financial support.
URI: http://hdl.handle.net/10045/37262
ISSN: 0003-2670 (Print) | 1873-4324 (Online)
DOI: 10.1016/j.aca.2014.04.016
Idioma: eng
Tipus: info:eu-repo/semantics/article
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.aca.2014.04.016
Apareix a la col·lecció: INV - SP-BG - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2014_Avila_etal_AnalyticaChimicaActa_final.pdfVersión final (acceso restringido)520,25 kBAdobe PDFObrir     Sol·licitar una còpia
Thumbnail2014_Avila_etal_AnalyticaChimicaActa.pdfVersión revisada (acceso abierto)147,75 kBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.