Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/37262
Títol: | Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry |
---|---|
Autors: | Ávila Orozco, Francisco D. | Kovachev, Nikolay | Aguirre Pastor, Miguel Ángel | Domini, Claudia E. | Fernández Band, Beatriz S. | Canals, Antonio |
Grups d'investigació o GITE: | Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | Universidad de Alicante. Instituto Universitario de Materiales |
Paraules clau: | Multinebulizer | ICP OES | Inorganic elemental analysis | Biodiesel |
Àrees de coneixement: | Química Analítica |
Data de publicació: | 27-de maig-2014 |
Editor: | Elsevier |
Citació bibliogràfica: | Analytica Chimica Acta. 2014, 827: 15-21. doi:10.1016/j.aca.2014.04.016 |
Resum: | A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring® multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R2) were greater than 0.99 for the studied analytes, in the range 0.21–14.75 mg kg−1. Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g−1 for Mg (279.553 nm) and 531.1 ng g−1 for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g−1 for Ba (455.403 nm) and 2913.9 ng g−1 for Pb (220.353 nm). Recovery values ranged between 95% and 106%. |
Patrocinadors: | The authors gratefully acknowledge Universidad Nacional del Sur (UNS) and Instituto de Química del Sur – Universidad Nacional del Sur – Consejo Nacional de Investigaciones Científicas y Técnicas (INQUISUR-UNS-CONICET) from Argentina for the financial support. FDAO acknowledges Universidad de Alicante (UA) for his short visit fellowship. Ministerio de Asuntos Exteriores y de Cooperación (MAEC) and Dirección de Relaciones Culturales y Científicas (AECID) from Spain for the financial support. The authors wish to thank the Spanish Government (CTQ2011-23968) for the financial support. |
URI: | http://hdl.handle.net/10045/37262 |
ISSN: | 0003-2670 (Print) | 1873-4324 (Online) |
DOI: | 10.1016/j.aca.2014.04.016 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1016/j.aca.2014.04.016 |
Apareix a la col·lecció: | INV - SP-BG - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
2014_Avila_etal_AnalyticaChimicaActa_final.pdf | Versión final (acceso restringido) | 520,25 kB | Adobe PDF | Obrir Sol·licitar una còpia |
2014_Avila_etal_AnalyticaChimicaActa.pdf | Versión revisada (acceso abierto) | 147,75 kB | Adobe PDF | Obrir Vista prèvia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.