Reducing preanalytical laboratory sample errors through educational and technological interventions

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/33562
Información del item - Informació de l'item - Item information
Título: Reducing preanalytical laboratory sample errors through educational and technological interventions
Autor/es: Lillo, Rosa | Salinas, María | López Garrigós, Maite | Naranjo Santana, Yurena | Gutiérrez, Mercedes | Marín, María Dolores | Miralles, Manuel | Uris Sellés, Joaquín
Grupo/s de investigación o GITE: Grupo Balmis de Investigación en Salud Comunitaria e Historia de la Ciencia
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Enfermería Comunitaria, Medicina Preventiva y Salud Pública e Historia de la Ciencia
Palabras clave: Improvement strategies | Laboratory errors | Patient safety | Preanalytical phase | Phlebotomy | Quality in laboratory
Área/s de conocimiento: Enfermería
Fecha de publicación: 2012
Editor: Clinical Laboratory Publications GmbH
Cita bibliográfica: Clinical Laboratory. 2012, 58 (9-10): 911-917. doi:10.7754/Clin.Lab.2012.111111
Resumen: Background: A correct preanalytical phase procedure is critical to get an adequate sample and consequently to achieve the most reliable laboratory results, promoting patient safety. Continuous laboratory staff changes create the need to establish improvement strategies to reduce the error risk. The objective was to show how the numbers of preanalytical errors related to unsuitable samples in a hospital setting decrease following two improvement strategies related to new technology and educational actions and how their effects were measured by monitoring indicators. Methods: Samples were drawn by the laboratory and other hospital departments’ nurses without previous patient appointment, therefore, prior tube preparation was not available before the phlebotomy. Corrective measures for these activities were established: educational program for nurses and a system of custom labels, which correlate each laboratory test in the Laboratory Information System (LIS) with the corresponding tube. Three phases were defined based on the implementation dates of the improvement actions to be assessed. The set of indicators de-signed to monitor the improvement related to clotted, hemolyzed, insufficient, and uncollected samples. Data were collected and indicators calculated from the LIS using a data warehouse application. Patient satisfaction with re-spect to phlebotomy was also measured annually using a scoring survey. Results: There was a reduction in all types of preanalytical sample errors related to the improvement strategies adopted. The indicators demonstrated that the unavailable, insufficient, and clotted samples decreased between two- and three-fold, whereas hemolysis errors benefited more from these improvement strategies. Patient satisfaction with the laboratory and phlebotomy procedures improved over the past several years as based on the annual satisfaction surveys. Conclusions: The educational program for nursing personnel is relevant and important as can be seen in the de-crease of sample errors and the resulting quality improvement. The custom label system minimizes the potential oversight of forgetting to draw a tube, which happens frequently when operating without appointments, by print-ing the labels according to requested tests. Detection, identification, and monitoring of the error and implement-ing strategies to improve preanalytical quality reduces error numbers and thereby improves patient safety and health system outcomes.
URI: http://hdl.handle.net/10045/33562
ISSN: 1433-6510
DOI: 10.7754/Clin.Lab.2012.111111
Idioma: eng
Tipo: info:eu-repo/semantics/article
Revisión científica: si
Versión del editor: http://dx.doi.org/10.7754/Clin.Lab.2012.111111
Aparece en las colecciones:INV - SALUD - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2012_Lillo_etal_ClinLab.pdf686,29 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.