Geometrical approximations for accurate evaluation of refraction in the human cornea

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/2066
Información del item - Informació de l'item - Item information
Título: Geometrical approximations for accurate evaluation of refraction in the human cornea
Autor/es: Espinosa, Julián | Rouarch, Jessica | Pérez Rodríguez, Jorge | Illueca Contri, Carlos | Mas, David
Grupo/s de investigación o GITE: Óptica y Ciencias de la Visión
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Transmitancia corneal | Coeficientes de Zernike | Ojo Humano | Aberraciones ópticas | Indice queratométrico personalizado | Corneal transmittance | Human eye | Personalized keratometric index | Optical aberrations | Zernike coefficients
Área/s de conocimiento: Óptica
Fecha de creación: 2005
Fecha de publicación: 7-may-2007
Editor: Elsevier
Cita bibliográfica: ESPINOSA TOMÁS, Julián, et al. “Geometrical approximations for accurate evaluation of refraction in the human cornea”. Optik. Vol. 118, Issue 5 (7 May 2007). ISSN 0030-4026, pp. 209-215
Resumen: Corneal analysis is usually done under two assumptions: first it is considered as a single surface that separates air from a medium with an equivalent keratometric index. The analysis is done under exact ray tracing, which leads to a non-uniformly sampled output pattern. In this paper we analyze both of these affirmations. We will first study the importance of the second corneal surface. We also propose several simplifications to the problem of calculating the transmittance of the cornea without resampling the output pattern. The different approximations will be analyzed by computing the differences in the optical path length covered by the light when passing the cornea. We will show that unique evaluation if absolute differences in the optical path is not the best criterion, since it fails in describing the spherical aberration. We will also analyze the absolute optical path function by decomposing it in Zernike polynomials. This criterion will lead us to determine whether approximations proposed are good enough to describe the cornea.
Patrocinador/es: This work has been partially supported by the Conselleria de Empresa, Universitat i Ciencia of the Generalitat Valenciana, through the Project no. GV04A/ 578, and by the Ministerio de Educación y Ciencia through the Project no. FIS2005-05053.
URI: http://hdl.handle.net/10045/2066
ISSN: 0030-4026
DOI: 10.1016/j.ijleo.2006.03.014
Idioma: eng
Tipo: info:eu-repo/semantics/article
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.ijleo.2006.03.014
Aparece en las colecciones:INV - IMAOS+V - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnailoptik07.pdfVersión final (acceso restringido)485,42 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.