The ordinary light microscope: an appropriate tool for provisional detection and identification of crystals in synovial fluid

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/17848
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorSalud Públicaen
dc.contributor.authorPascual, Eliseo-
dc.contributor.authorTovar, Juan-
dc.contributor.authorRuiz-Cantero, María Teresa-
dc.contributor.otherUniversidad de Alicante. Departamento de Enfermería Comunitaria, Medicina Preventiva y Salud Pública e Historia de la Cienciaen
dc.date.accessioned2011-06-30T11:31:07Z-
dc.date.available2011-06-30T11:31:07Z-
dc.date.issued1989-12-
dc.identifier.citationPASCUAL, E.; TOVAR, J.; RUIZ, M.T.. “The ordinary light microscope: an appropriate tool for provisional detection and identification of crystals in synovial fluid”. Annals of the Rheumatic Diseases. Vol. 48, No. 12 (Dec. 1989). ISSN 0003-4967, pp. 983-985en
dc.identifier.issn0003-4967 (Print)-
dc.identifier.issn1468-2060 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/17848-
dc.description.abstractTo determine if the ordinary light microscope is a useful tool in the detection and identification of crystals in synovial fluid 63 fluids (13 with monosodium urate (MSU), 14 with calcium pyrophosphate dihydrate (CPPD), one with both types of crystal, and 35 without crystals) were examined blindly by two observers, first with an ordinary light microscope, then with a polarising light microscope. Tentative identification of the crystals by their shape was attempted. The sensitivity of the ordinary light microscope for the detection of crystals was 96.2% and 100%, with specificity of 100% and 97.1% for observers 1 and 2, both with respect to the polarising light microscope. The concordance between observers for the ordinary light microscope was chi = 0.90 (0.897, 0.902) and for the polarising light microscope chi = 0.96 (0.958, 0.961). The specificity for identification of MSU and CPPD crystals by their shape with respect to the polarising light microscope was 92.3% and 85.7% for observers 1 and 2. When a polarising light microscope is not available examination of synovial fluid by an ordinary light microscope may allow a provisional diagnosis; definitive identification of the crystals requires a polarising light microscope.en
dc.languageengen
dc.publisherBMJ Publishing Groupen
dc.rightsAnnals of the Rheumatic Diseases. http://ard.bmj.com/en
dc.subjectSynovial fluiden
dc.subjectMSUen
dc.subjectCPPDen
dc.subject.otherMedicina Preventiva y Salud Públicaen
dc.titleThe ordinary light microscope: an appropriate tool for provisional detection and identification of crystals in synovial fluiden
dc.typeinfo:eu-repo/semantics/articleen
dc.peerreviewedsien
dc.identifier.doi10.1136/ard.48.12.983-
dc.relation.publisherversionhttp://dx.doi.org/10.1136/ard.48.12.983en
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessen
Aparece en las colecciones:INV - SP - Artículos de Revistas
Institucional - IUIEG - Publicaciones

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailThe ordinary light microscope.pdfVersión final (acceso restringido)783,9 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.