Reliability and Agreement of Keratometry Measurements Obtained With Eye Surface Profilometry and Partial Coherence Interferometry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/140873
Información del item - Informació de l'item - Item information
Título: Reliability and Agreement of Keratometry Measurements Obtained With Eye Surface Profilometry and Partial Coherence Interferometry
Autor/es: Martínez-Plaza, Elena | Molina-Martín, Ainhoa | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Keratometry | Corneal radius | Eye Surface Profiler | Reliability
Fecha de publicación: mar-2024
Editor: Wolters Kluwer
Cita bibliográfica: Cornea. 2024, 43(3): 343-348. https://doi.org/10.1097/ICO.0000000000003348
Resumen: Purpose: The aim of this study was to assess the repeatability of keratometry parameters obtained using the Eye Surface Profiler (ESP) system and their agreement with the IOL Master 500 device. Methods: Seventy-one eyes of 71 healthy participants were evaluated. Three repeated measurements were performed using the ESP system. Simulated keratometry in the flat (SimKf) and steep (SimKs) meridians, astigmatism, and axis were obtained. The same parameters were measured using the IOL Master 500 device. The J0 and J45 vector components of the astigmatism were calculated. The intrasession repeatability was analyzed using within-subject SD (Sw) and intraclass correlation coeffi cient (ICC). Agreement was assessed using paired statistical tests and the Bland–Altman method. Results: The Sw was 0.07 mm, 0.04 mm, 0.51 D, 0.33 D, and 0.22 D, and the ICC was 0.96, 0.98, 0.74, 0.61, and 0.55 for SimKf, SimKs, astigmatism, J0, and J45, respectively. The mean difference and limits of agreement when comparing the ESP system with the IOL Master 500 device were 0.37 mm (0.08/0.66) for SimKf (P , 0.001), 0.18 mm (0.00/0.35) for SimKs (P , 0.001), 20.93 D (22.42/0.56) for astigmatism (P , 0.001), 0.51 D (20.22/1.24) for J0 (P , 0.001), and 0.06 D (20.48/0.60) for J45 (P = 0.09). Conclusions: The ESP system provides consistent values for simulated keratometry, showing moderate consistency for astigma tism parameters. Contact lens practitioners should be aware that the ESP system and IOL Master 500 device provide different simulated keratometry from a clinically viewpoint.
Patrocinador/es: E.M.-P. has been supported by European Union-NextGenerationEU.
URI: http://hdl.handle.net/10045/140873
ISSN: 0277-3740 (Print) | 1536-4798 (Online)
DOI: 10.1097/ICO.0000000000003348
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2023 Wolters Kluwer Health, Inc.
Revisión científica: si
Versión del editor: https://doi.org/10.1097/ICO.0000000000003348
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailMartinez-Plaza_etal_2024_Cornea_final.pdfVersión final (acceso restringido)558,6 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.