Microwave-sustained inductively coupled atmospheric-pressure plasma (MICAP) for the elemental analysis of complex matrix samples

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/139764
Información del item - Informació de l'item - Item information
Título: Microwave-sustained inductively coupled atmospheric-pressure plasma (MICAP) for the elemental analysis of complex matrix samples
Autor/es: Serrano, Raquel | Grindlay, Guillermo | Gras, Luis | Mora, Juan
Grupo/s de investigación o GITE: Espectrometría Atómica Analítica (GEAA)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Palabras clave: Microwave plasma | Optical emission spectrometry | Metals | Environmental | Food | Polymers
Fecha de publicación: 14-ene-2024
Editor: Elsevier
Cita bibliográfica: Talanta. 2024, 271: 125666. https://doi.org/10.1016/j.talanta.2024.125666
Resumen: Microwave induced plasma optical emission spectrometry (MIP-OES) has gained widespread attention in the last few years for trace elemental analysis. Among the new generation of MIPs it is worth to mention the microwave-sustained inductively coupled atmospheric-pressure plasma (MICAP) for which previous works have shown similar detection capabilities to those afforded by ICP-OES. Nevertheless, this instrument has not been applied yet to complex matrix sample analysis. Therefore, the goal of this work is to evaluate MICAP-OES performance (e.g., analytical figures of merit, matrix effects, etc.) for elemental analysis of samples of different nature (e.g., environmental, food and polymers). To this end, both spectral and non-spectral interferences were investigated for 19 elements (Ag, Al, As, B, Ca, Cd, Co, Cr, Cu, Fe, Ga, In, Mg, Mn, Ni, Pb, Sr, Tl, Zn) in the presence of inorganic acid, organic and saline solutions and compared to a 5 % w w−1 HNO3 solution. Unlike previous MIPs, experimental data showed that the optimum nebulizer gas flow rate for a given emission wavelength was mostly independent of matrix characteristics. Regarding matrix effects, this device was highly robust operating both inorganic acid and organic matrices. Interestingly, when operating saline matrices, changes on emission signal by easily ionizable elements were less significant than those early reported by alternative MIP cavities. Moreover, due to MICAP spectrometer design employed allows real-time simultaneous analysis, Rh, Pd, Sc and Y were suitable internal standards to minimize non-spectral interferences. Finally, MICAP-OES can be successfully applied to the elemental analysis of different complex matrix samples (i.e., CRM-DW1 Drinking water; BCR-146 Sewage sludge industrial; BCR-185 Bovine liver; BCR-278R Mussel tissue; NIST-1549 Non-fat milk powder; ERM-EC681k Polyethylene (high level) and BCR-483 Sewage sludge amended soil).
Patrocinador/es: This research was funded by the University of Alicante through research projects VIGROB-050.
URI: http://hdl.handle.net/10045/139764
ISSN: 0039-9140 (Print) | 1873-3573 (Online)
DOI: 10.1016/j.talanta.2024.125666
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2024 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Revisión científica: si
Versión del editor: https://doi.org/10.1016/j.talanta.2024.125666
Aparece en las colecciones:INV - GEAA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailSerrano_etal_2024_Talanta.pdf2,72 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.