Efficacy of Presbyopia-Correcting Contact Lenses: A Systematic Review

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/136947
Información del item - Informació de l'item - Item information
Título: Efficacy of Presbyopia-Correcting Contact Lenses: A Systematic Review
Autor/es: Molina-Martín, Ainhoa | Piñero, David P. | Martínez-Plaza, Elena | Rodríguez-Vallejo, Manuel | Fernández, Joaquín
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Multifocal contact lens | Simultaneous vision | Pinhole | Monovision | EDOF contact lens | Spherical aberration | Presbyopia
Fecha de publicación: ago-2023
Editor: Wolters Kluwer
Cita bibliográfica: Eye & Contact Lens: Science & Clinical Practice. 2023, 49(8): 319-328. https://doi.org/10.1097/ICL.0000000000001013
Resumen: Purpose: To analyze critically the clinical trials on presbyopia correction with contact lenses (CLs) to investigate the quality of the research performed. Methods: A search was performed in PubMed database on clinical trials evaluating the efficacy of the presbyopia correction with different CLs, including multifocal or simultaneous vision contact lenses (MCLs). After a comprehensive analysis of the relevant publications found, quality assessment of such publications was performed by means of Critical Appraisal Skills Programme checklist tool according to the five types of evaluations: MCL versus spectacles, MCL versus pinhole CLs, MCL versus monovision, comparison between MCL designs, and MCL versus extended depth of focus CLs. Results: A total of 16 clinical trials were selected for evaluation. All evaluated studies addressed a clearly focused research question and were randomized, with a crossover design in most of the cases. Blinding was not possible in all cases due to the physical appearance of some of the CLs evaluated (pinhole or hybrid designs). Most of studies analyzed reported outcomes with complete data, providing the statistical tests used and the P-values, but some of the authors did not provide the statistical power associated to the sample size evaluated. The small sample size in some trials as well as the scarce information about the effect of addition on visual performance was the main limitations found in the peer-reviewed literature revised. Conclusions: There is a high-quality scientific evidence supporting the use of presbyopia-correcting CLs, with several randomized controlled clinical trials conducted to this date.
URI: http://hdl.handle.net/10045/136947
ISSN: 1542-2321 (Print) | 1542-233X (Online)
DOI: 10.1097/ICL.0000000000001013
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2023 Contact Lens Association of Ophthalmologists
Revisión científica: si
Versión del editor: https://doi.org/10.1097/ICL.0000000000001013
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailMolina-Martin_etal_2023_EyeContactLens_final.pdfVersión final (acceso restringido)428,53 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.