Modified MSIS chamber as novel gas-liquid separator coupled with photochemical vapor generation of trace mercury with MP-AES detection
Please use this identifier to cite or link to this item:
http://hdl.handle.net/10045/136907
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor | Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas | es_ES |
dc.contributor.author | Stoitsov, Dimitar | - |
dc.contributor.author | Kmetov, Veselin Y. | - |
dc.contributor.author | Canals, Antonio | - |
dc.contributor.other | Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología | es_ES |
dc.date.accessioned | 2023-09-04T11:57:20Z | - |
dc.date.available | 2023-09-04T11:57:20Z | - |
dc.date.issued | 2023-08-30 | - |
dc.identifier.citation | Journal of Analytical Atomic Spectrometry. 2023, 38: 1920-1926. https://doi.org/10.1039/D3JA00207A | es_ES |
dc.identifier.issn | 0267-9477 (Print) | - |
dc.identifier.issn | 1364-5544 (Online) | - |
dc.identifier.uri | http://hdl.handle.net/10045/136907 | - |
dc.description.abstract | New hyphenation of continuous flow photochemical vapor generator (PVG) to modified multimode sample introduction system (MSIS) used as gas-liquid separator and microwave plasma atomic emission spectrometry (MP-AES) was proposed for analysis of trace mercury. The widened MSIS bottom inlet contributes to the increase of the Hg0 mass transfer in the gas-liquid separator allowing the mercury determination by MP-AES. After optimizing the PVG reactor conditions and MP-AES instrument parameters a limit of detection (LOD) of 0.25 ppb was obtained for Hg2+. The applicability of the PVG-MSIS-MP-AES method was subsequently demonstrated for trace mercury analysis in two soil CRMs - ERM-CC135a (Contaminated Brickworks soil) and CRM005 (Sewage Amended soil). | es_ES |
dc.description.sponsorship | This study is financed by the European Union-NextGenerationEU, through the National Recovery and Resilience Plan of the Republic of Bulgaria, project № BG-RRP-2.004-0001-C01. | es_ES |
dc.language | eng | es_ES |
dc.publisher | Royal Society of Chemistry | es_ES |
dc.rights | © Royal Society of Chemistry | es_ES |
dc.subject | Photochemical vapor generation | es_ES |
dc.subject | MSIS | es_ES |
dc.subject | MP-AES detection | es_ES |
dc.subject | Gas-liquid separator | es_ES |
dc.subject | Trace mercury | es_ES |
dc.title | Modified MSIS chamber as novel gas-liquid separator coupled with photochemical vapor generation of trace mercury with MP-AES detection | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.peerreviewed | si | es_ES |
dc.identifier.doi | 10.1039/D3JA00207A | - |
dc.relation.publisherversion | https://doi.org/10.1039/D3JA00207A | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/embargoedAccess | es_ES |
dc.date.embargoEnd | info:eu-repo/date/embargoEnd/2024-08-31 | es_ES |
Appears in Collections: | INV - SP-BG - Artículos de Revistas |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Stoitsov_etal_2023_JAnalAtSpectrom_accepted.pdf | Embargo 12 meses (acceso abierto: 31 ag. 2024) | 1,02 MB | Adobe PDF | Open Request a copy |
Stoitsov_etal_2023_JAnalAtSpectrom_final.pdf | Versión final (acceso restringido) | 405,86 kB | Adobe PDF | Open Request a copy |
Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.