Assessment of total sample consumption infrared-heated system for minimization of matrix effects in ICP-tandem mass spectrometry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/136840
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorAnálisis de Polímeros y Nanomaterialeses_ES
dc.contributor.authorSánchez, Raquel-
dc.contributor.authorTodolí Torró, José Luis-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaes_ES
dc.date.accessioned2023-08-29T10:45:33Z-
dc.date.available2023-08-29T10:45:33Z-
dc.date.issued2023-08-20-
dc.identifier.citationSpectrochimica Acta Part B: Atomic Spectroscopy. 2023, 208: 106779. https://doi.org/10.1016/j.sab.2023.106779es_ES
dc.identifier.issn0584-8547 (Print)-
dc.identifier.issn1873-3565 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/136840-
dc.description.abstractA total sample consumption infrared-heated system (IR-TSC) has been coupled to ICP-tandem mass spectrometry (ICP-MS/MS) for the first time. The objective of this study was to assess the analytical performance of the IR-TSC system, in terms of analytical figures of merit and mitigation of matrix effects. Twenty-seven elements have been determined: Ag, Al, As, B, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, K, Li, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sn, Sr, Ti, Tl, V and Zn. Different operating conditions, including nebulization flow rate and spray chamber temperature, were optimized to improve sensitivity, signal stability, and plasma thermal conditions. The results showed that the infrared-heated sample introduction system improved the signal intensity by a factor of 2 to 4 compared to a conventional sample introduction system, whereas the limits of detection (LODs) improved by a factor going from 1.2 (Ba) to 3.3 (Cr) for a sample containing 2% HNO3. Meanwhile, for a 10% ethanol sample the improvement factor ranged from 1.4 (Ti) to 3.8 (Cr). Matrix effects for solutions containing inorganic acids or high content of sodium (2% HNO3, 10% HNO3, 20% HNO3, 10% HCl; 500 mg kg−1 Na, 500 mg kg−1 Na + 10% HNO3) were mitigated under optimum conditions (IR-TSC at 125 °C). Meanwhile, for solutions containing organic solvents (10% ethanol, 10% acetic acid, and 10% formic acid) it was not possible to eliminate matrix effects, even when applying an internal standard. For Se and As, elements spectrally interfered, the combination of IR-TSC sample introduction system with oxygen as reaction/collision gas mode in ICP-MS/MS provided accurate results. For 10% HNO3 and 10% HCl relative intensities values, calculated taking the signal intensity obtained for 2% HNO3 as reference, were close to the unity. Environmental and clinical control and certified reference materials were analyzed by means of an external calibration approach, with most of the elements showing concentrations not significantly different from the certified values. Finally, the IR-TSC was tested on twelve real samples, including seawater, surface water, peritoneal fluid, seminal plasma, wine, and bioethanol samples, demonstrating the system potential in different application fields.es_ES
dc.description.sponsorshipThe authors wish to thank the Spanish Ministry of Science, Innovation, and Universities for the financial support (Projects Ref. PGC2018-100711-B-I00 and PID2021-127566NB-I00).es_ES
dc.languageenges_ES
dc.publisherElsevieres_ES
dc.rights© 2023 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).es_ES
dc.subjectTotal sample consumption infrared-heated system (IR-TSC)es_ES
dc.subjectICP-MS/MSes_ES
dc.subjectMetal contentes_ES
dc.subjectMatrix effects, polyatomic interferenceses_ES
dc.titleAssessment of total sample consumption infrared-heated system for minimization of matrix effects in ICP-tandem mass spectrometryes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.1016/j.sab.2023.106779-
dc.relation.publisherversionhttps://doi.org/10.1016/j.sab.2023.106779es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PGC2018-100711-B-I00es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2021-127566NB-I00es_ES
Aparece en las colecciones:INV - NANOBIOPOL - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailSanchez_Todoli_2023_SpectrochimActaPartB.pdf3,63 MBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons