Evaluation of a microwave desolvation system in inductively coupled plasma mass spectrometry with low acid concentration solutions

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/13618
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorEspectrometría Atómica Analíticaen
dc.contributor.authorMora, Juan-
dc.contributor.authorHernandis Martínez, Vicente-
dc.contributor.authorVeen, Eric H. van-
dc.contributor.authorLoos-Vollebregt, Margaretha T.C. de-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaen
dc.contributor.otherDelft University of Technology. Laboratory of Materials Scienceen
dc.date.accessioned2010-03-16T11:43:25Z-
dc.date.available2010-03-16T11:43:25Z-
dc.date.issued1998-03-
dc.identifier.citationMORA PASTOR, Juan, et al. “Evaluation of a microwave desolvation system in inductively coupled plasma mass spectrometry with low acid concentration solutions”. Journal of Analytical Atomic Spectrometry (JAAS). Vol. 13, Issue 3 (1998). ISSN 0267-9477, pp. 175-181en
dc.identifier.issn0267-9477 (Print)-
dc.identifier.issn1364-5544 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/13618-
dc.description.abstractThe behaviour of a desolvation system based on microwave heating (termed a microwave desolvation system, MWDS) with low acid concentration solutions was evaluated in inductively coupled plasma mass spectrometry. Studies included water, sulfuric acid, perchloric acid, nitric acid and hydrochloric acid. The best performance of the MWDS was obtained at low liquid uptake rate and low acid concentrations. The analytical behaviour of the MWDS depends on the nature and composition of the solution used. In comparison with water, acid solutions provide up to four times higher ion intensities for the elements tested. In comparison with nitric and hydrochloric acid, sulfuric and perchloric acid provide higher ion intensities but also higher CeO+/Ce+ ratios whereas Ba2+/Ba+ ratios are lower. The limits of detection (LODs) are of the same order of magnitude for all acid solutions used, unless the specific isotope/solvent combinations suffer from spectral interference. In comparison with the conventional sample introduction (CS) without desolvation system the MWDS provides between 2 and 14 times higher ion intensities for the isotopes tested. For nitric and hydrochloric acid solutions the MWDS gives rise to lower CeO+/Ce+ratios and higher Ba2+/Ba+ ratios. For sulfuric and perchloric acid these tendencies are the opposite. For the isotopes that are not subject to interference, the LODs obtained with the MWDS are up to a factor of 10 lower than those obtained with CS.en
dc.description.sponsorshipDGICyT (Spain) (Project PB95–0693).en
dc.languageengen
dc.publisherRoyal Society of Chemistryen
dc.subjectMicrowave desolvationen
dc.subjectAcid solutionen
dc.subjectInductively coupled plasma mass spectrometryen
dc.subjectOxide levelen
dc.subjectDoubly-charged ion levelen
dc.subjectPolyatomic spectral interferenceen
dc.subject.otherQuímica Analíticaen
dc.titleEvaluation of a microwave desolvation system in inductively coupled plasma mass spectrometry with low acid concentration solutionsen
dc.typeinfo:eu-repo/semantics/articleen
dc.peerreviewedsien
dc.identifier.doi10.1039/a706833f-
dc.relation.publisherversionhttp://dx.doi.org/10.1016/10.1039/a706833fen
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Aparece en las colecciones:INV - GEAA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailMWDS en ICPMS.pdf232,01 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.