Refractive and aberrometric outcomes of intracorneal ring segments for keratoconus: mechanical versus femtosecond-assisted procedures

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/13601
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorHolografía y Procesado Ópticoen
dc.contributor.authorPiñero, David P.-
dc.contributor.authorAlió y Sanz, Jorge L.-
dc.contributor.authorEl Kady, Bassam-
dc.contributor.authorCoskunseven, Efekan-
dc.contributor.authorMorbelli, Héctor-
dc.contributor.authorUceda Montañés, Antonio-
dc.contributor.authorMaldonado, Miguel J.-
dc.contributor.authorCuevas, Diego-
dc.contributor.authorPascual, Inmaculada-
dc.contributor.otherUniversidad de Alicante. Departamento de Óptica, Farmacología y Anatomíaen
dc.contributor.otherUniversidad Miguel Hernández. División de Oftalmologíaen
dc.contributor.otherVissum / Instituto Oftalmológico de Alicanteen
dc.contributor.otherAin Shams University (El Cairo)en
dc.contributor.otherDunya Eye Hospital (Estambul)en
dc.contributor.otherVissum Albaceteen
dc.contributor.otherVissum Sevillaen
dc.contributor.otherFundación Andaluza de Imagen, Color y Óptica (Sevilla)en
dc.contributor.otherClínica Universitaria de Navarra. Departamento de Oftalmologíaen
dc.contributor.otherVissum Almeríaen
dc.date.accessioned2010-03-10T11:35:04Z-
dc.date.available2010-03-10T11:35:04Z-
dc.date.created2008-12-19-
dc.date.issued2009-09-01-
dc.identifier.citationPIÑERO LLORENS, David Pablo, et al. "Refractive and aberrometric outcomes of intracorneal ring segments for keratoconus: mechanical versus femtosecond-assisted procedures". Ophthalmology. Vol. 116, No. 9 (Sept. 2009). ISSN 0161-6420, pp. 1675-1687en
dc.identifier.issn0161-6420-
dc.identifier.urihttp://hdl.handle.net/10045/13601-
dc.descriptionFinancial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article.en
dc.description.abstractObjective: To compare visual, refractive, and corneal aberrometric outcomes in keratoconic eyes implanted with intracorneal ring segments (ICRS) implantation using either a mechanical or a femtosecond laser-assisted procedure. Design: Retrospective, consecutive case series. Participants: A total of 146 consecutive eyes of 106 patients with the diagnosis of keratoconus (68 unilateral and 39 bilateral) were included. Two groups were created according to the surgical technique used for corneal tunnelization: Mechanical group (mechanical tunnelization, 63 eyes) and Femtosecond group (femtosecond laser-assisted tunnelization, 83 eyes). Intracorneal ring segments implantation was indicated because of the existence of reduced best spectacle-corrected visual acuity (BSCVA) or contact lens intolerance. Methods: Intracorneal ring segments implantations were performed by 6 surgeons following the same protocol except for the incision location. A total of 55 eyes were implanted with Intacs (Addition Technology, Inc, Fremont, CA) and 8 eyes were implanted with KeraRings (Mediphacos, Belo Horizonte, Brazil) in the Mechanical group, and 25 eyes were implanted with Intacs and 58 eyes were implanted with KeraRings in the Femtosecond group. Mean follow-up was 10.66±8.20 months, ranging from 1 month to 24 months. Main Outcome Measures: Uncorrected visual acuity (UCVA), BSCVA, refraction, keratometry, and root mean square (RMS) for different kinds of corneal aberrations. Results: By reporting only for statistically significant changes, UCVA improved in both groups at 6 months (P≤0.02) and BSCVA improved in the Femtosecond group (P<0.01). The refraction improved in both groups at 6 months (P≤0.02). The cornea on average was flatter in both groups at 6 months (P<0.01). Root mean square astigmatism was reduced in the Femtosecond group (P = 0.03), but there was an increase in some higher-order aberrations (P = 0.03). Significant differences were found between the 2 groups for eyes implanted with Intacs for primary spherical aberration, coma, and other higher-order aberrations, favoring the Femtosecond group (P≤0.01). A significant negative correlation was found between the preoperative corneal aberrations and the postoperative BSCVA in the Mechanical group (r>0.63, P≤0.04). Conclusions: Intracorneal ring segments implantation using both mechanical and femtosecond laser-assisted procedures provide similar visual and refractive outcomes. A more limited aberrometric correction is observed for eyes with mechanical implantation.en
dc.description.sponsorshipSupported in part by a grant of the Spanish Ministry of Health, Instituto Carlos III, Red Temática de Investigación Cooperativa en Salud “Patología ocular del envejecimiento, calidad visual y calidad de vida,” Subproyecto de Calidad Visual (RD07/0062).en
dc.languageengen
dc.publisherElsevieren
dc.rights© 2009 by the American Academy of Ophthalmologyen
dc.subjectIntracorneal ring segment implantationen
dc.subjectRefractive outcomeen
dc.subject.otherOftalmologíaen
dc.subject.otherÓpticaen
dc.titleRefractive and aberrometric outcomes of intracorneal ring segments for keratoconus: mechanical versus femtosecond-assisted proceduresen
dc.typeinfo:eu-repo/semantics/articleen
dc.peerreviewedsien
dc.identifier.doi10.1016/j.ophtha.2009.05.016-
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.ophtha.2009.05.016en
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess-
Aparece en las colecciones:INV - GHPO - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailOphtha_v116_n9_p1675_2009.pdfVersión final (acceso restringido)841,37 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.