A microwave assisted desolvation system based on the use of a TM010 cavity for inductively coupled plasma based analytical techniques

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/13403
Información del item - Informació de l'item - Item information
Título: A microwave assisted desolvation system based on the use of a TM010 cavity for inductively coupled plasma based analytical techniques
Autor/es: Grindlay, Guillermo | Maestre, Salvador E. | Mora, Juan | Hernandis Martínez, Vicente | Gras, Luis
Grupo/s de investigación o GITE: Espectrometría Atómica Analítica | Análisis de Alimentos
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Palabras clave: Microwave radiation | Desolvation system | ICP-AES | ICP-MS | Microwave desolvation | Sample introduction system
Área/s de conocimiento: Química Analítica
Fecha de publicación: 29-mar-2005
Editor: Royal Society of Chemistry
Cita bibliográfica: GRINDLAY LLEDÓ, Guillermo, et al. “A microwave assisted desolvation system based on the use of a TM010 cavity for inductively coupled plasma based analytical techniques”. Journal of Analytical Atomic Spectrometry (JAAS). Vol. 20, Issue 5 (2005). ISSN 0267-9477, pp. 455-461
Resumen: A new microwave assisted desolvation system based on the use of a TM010 cavity (MWDS2) has been developed and evaluated in plasma based analytical techniques: inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The new design overcomes the main experimental drawbacks shown by previous designs based on the use of domestic ovens: (i) lack of control on microwave generation and application; and (ii) inappropriate MW cavity characteristics. The evaluation has been performed in terms of the effect of the incident microwave power and the sample uptake rate and the results obtained has been compared with those afforded by a conventional sample introduction system (nebulizer and double pass spray chamber) and a desolvation system based on the use of a domestic microwave oven (MWDS). The new MWDS2 give rise to higher analytical signals and lower limits of detection and stabilization times (2–3 times) than those obtained with the MWDS in ICP-AES and ICP-MS.
URI: http://hdl.handle.net/10045/13403
ISSN: 0267-9477 (Print) | 1364-5544 (Online)
DOI: 10.1039/b418282k
Idioma: eng
Tipo: info:eu-repo/semantics/article
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1039/b418282k
Aparece en las colecciones:INV - GEAA - Artículos de Revistas
INV - AAQCN - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailMDWS TM010.pdf621,28 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.