Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/13402
Información del item - Informació de l'item - Item information
Título: Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry
Autor/es: Grindlay, Guillermo | Mora, Juan | Gras, Luis | Loos-Vollebregt, Margaretha T.C. de
Grupo/s de investigación o GITE: Espectrometría Atómica Analítica
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Palabras clave: Electrothermal vaporization | ICP-MS | As | Pb | Se | Wine
Área/s de conocimiento: Química Analítica
Fecha de publicación: 21-may-2009
Editor: Elsevier
Cita bibliográfica: GRINDLAY LLEDÓ, Guillermo, et al. “Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry”. Analytica Chimica Acta. Vol. 652, Issues 1-2 (12 Oct. 2009). ISSN 0003-2670, pp. 154-160
Resumen: The determination of Pb, Se and As in wine has a great interest due to health risks and legal requirements. To perform the analysis of wine, two considerations must be taken into account: (i) the low concentration level of the analytes; and (ii) the risk of interferences due to wine matrixcomponents. The goal of this work is to evaluate electrothermal vaporization (ETV)sample introduction for ultratrace determination of Pb, Se and As in wine samples by inductively coupled plasma mass spectrometry (ICP-MS). The results obtained with ETV-ICP-MS were compared to those obtained with conventional liquid sample introduction in ICP-MS and electrothermal atomic absorption spectrometry (ETAAS). Analytical figures of merit of ETV sample introduction strongly depend on the amount of wine sample, on the modifier nature (i.e. Pd, ascorbic acid or citric acid) and concentration and on the temperature program. Wine matrix components exert a great influence on analyte transport efficiency. Due to this fact, the analysis of wine cannot be performed by means of external calibration but the standard addition methodology should be used. The determination of Pb and Se in wine by ETV-ICP-MS provides similar results as conventional liquid sample introduction ICP-MS. For As, the concentration values obtained with ETV sample introduction were between two and four times lower than with the conventional system. These differences are related to the lower intensity of polyatomic interferences obtained for ETV sample introduction when compared to the conventional system. Finally, no differences for Pb determination were observed between ETV sample introduction and ETAAS. Unfortunately, the limits of detection for As and Se in ETAAS were not low enough to quantify these elements in the wine samples tested.
URI: http://hdl.handle.net/10045/13402
ISSN: 0003-2670 (Print) | 1873-4324 (Online)
DOI: 10.1016/j.aca.2009.05.020
Idioma: eng
Tipo: info:eu-repo/semantics/article
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1016/j.aca.2009.05.020
Aparece en las colecciones:INV - GEAA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailWine samples ETV-ICPMS ACA 652 (2009) 154.pdfVersión final (acceso restringido)437,24 kBAdobe PDFAbrir    Solicitar una copia
ThumbnailACA_229933_author_corrected.pdfVersión revisada (acceso libre)632,58 kBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.